![Main Product Image](https://assets.aleta.hr/415x415/b10c8d57-89dc-48ff-913a-4c6b11218950.webp)
![Main Product Image](https://assets.aleta.hr/415x415/b10c8d57-89dc-48ff-913a-4c6b11218950.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP30
Type of control element
Toggle
Number of poles
3
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
250A
Motor drive integrated
No
Rated voltage
750 - 750V
Overload release current setting
- - -A
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Yes
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
- - -A
Suitable for DIN rail (top hat rail) mounting
No
With under voltage release
No
With switched-off indicator
Yes
Adjustment range short-term delayed short-circuit release
- - -A
Position of connection for main current circuit
Front side
Integrated earth fault protection
No
Complete device with protection unit
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
DIN rail (top hat rail) mounting optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LV438203
![Main Product Image](https://assets.aleta.hr/300x300/63ff7ad1-4f62-445f-b9ff-06e97b0157cd_optimized.webp)
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- SCHNEIDER
Technical specifications
Degree of protection (IP)
IP30
Type of control element
Toggle
Number of poles
3
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Rated permanent current Iu
250A
Motor drive integrated
Rated voltage
750 .. 750V
Overload release current setting
- .. -A
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as change-over contact
0
Motor drive optional
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
- .. -A
Suitable for DIN rail (top hat rail) mounting
With under voltage release
With switched-off indicator
Adjustment range short-term delayed short-circuit release
- .. -A
Position of connection for main current circuit
Front side
Integrated earth fault protection
Complete device with protection unit
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
36kA
DIN rail (top hat rail) mounting optional
From same serie