Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
Yes
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
380 - 400V
Rated power, 460 V, 60 Hz, 3-phase
4kW
Rated operation current Ie
9A
Rated control supply voltage Us at AC 60HZ
380 - 400V
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Ambient temperature, upper operating limit
40°C
Rated operation power at AC-3, 400 V
4kW
Release class
CLASS 10
Rated operation current at AC-3, 400 V
9A
Voltage type for actuating
AC
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
6 - 10A
Type of electrical connection of main circuit
Screw connection
Temperature compensated overload protection
Yes
Number of command positions
5
Rail mounting possible
No
Degree of protection (IP)
IP55
Suitable for emergency stop
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
With transformer
No
External reset possible
No
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for CAN
No
Height
165mm
With fuse
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Depth
177mm
Number of indicator lights
0
Supporting protocol for ASI
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Width
175mm
Supporting protocol for SafetyBUS p
No
From same serie
LG7K09Q714

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
380 .. 400V
Rated power, 460 V, 60 Hz, 3-phase
4kW
Rated operation current Ie
9A
Rated control supply voltage Us at AC 60HZ
380 .. 400V
Number of auxiliary contacts as normally open contact
0
Rated conditional short-circuit current, type 1, 480 Y/277 V
10000A
Rated operation power at AC-3, 230 V, 3-phase
1.5kW
Ambient temperature, upper operating limit
40°C
Rated operation power at AC-3, 400 V
4kW
Release class
CLASS 10
Rated operation current at AC-3, 400 V
9A
Voltage type for actuating
AC
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
6 .. 10A
Type of electrical connection of main circuit
Screw connection
Temperature compensated overload protection
Number of command positions
5
Rail mounting possible
Degree of protection (IP)
IP55
Suitable for emergency stop
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
With transformer
External reset possible
Coordination class according to IEC 60947-4-3
Class 1
Supporting protocol for CAN
Height
165mm
With fuse
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Depth
177mm
Number of indicator lights
0
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Width
175mm
Supporting protocol for SafetyBUS p
From same serie