Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 230 V
-A
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated power, 460 V, 60 Hz, 3-phase
5.5kW
Overload release current setting
9 - 14A
Rated operation power at AC-3, 400 V
5.5kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
6000A
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
220 - 220V
With short-circuit release
Yes
Rated operation current Ie
12A
Rated control supply voltage Us at AC 60HZ
220 - 220V
Type of motor starter
Direct online starter (DOL)
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
40°C
Rated conditional short-circuit current, type 1, 600 Y/347 V
3000A
Release class
CLASS 10
Temperature compensated overload protection
Yes
Type of electrical connection of main circuit
Screw connection
Rail mounting possible
No
Suitable for emergency stop
Yes
Coordination class according to IEC 60947-4-3
Class 1
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
No
Number of command positions
5
Number of auxiliary contacts as normally closed contact
0
External reset possible
No
Rated operation current at AC-3, 400 V
12A
Number of indicator lights
0
Supporting protocol for INTERBUS
No
Supporting protocol for PROFIBUS
No
Degree of protection (IP)
IP55
With fuse
No
Supporting protocol for Modbus
No
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
No
Supporting protocol for Data-Highway
No
Supporting protocol for ASI
No
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Width
175mm
Height
165mm
Depth
165mm
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LG1D122M716

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated conditional short-circuit current, type 2, 400 V
-A
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 2, 230 V
-A
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated power, 460 V, 60 Hz, 3-phase
5.5kW
Overload release current setting
9 .. 14A
Rated operation power at AC-3, 400 V
5.5kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
6000A
Voltage type for actuating
AC
Rated control supply voltage Us at AC 50HZ
220 .. 220V
With short-circuit release
Rated operation current Ie
12A
Rated control supply voltage Us at AC 60HZ
220 .. 220V
Type of motor starter
Direct online starter (DOL)
Number of auxiliary contacts as normally open contact
0
Ambient temperature, upper operating limit
40°C
Rated conditional short-circuit current, type 1, 600 Y/347 V
3000A
Release class
CLASS 10
Temperature compensated overload protection
Type of electrical connection of main circuit
Screw connection
Rail mounting possible
Suitable for emergency stop
Coordination class according to IEC 60947-4-3
Class 1
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
Number of command positions
5
Number of auxiliary contacts as normally closed contact
0
External reset possible
Rated operation current at AC-3, 400 V
12A
Number of indicator lights
0
Supporting protocol for INTERBUS
Supporting protocol for PROFIBUS
Degree of protection (IP)
IP55
With fuse
Supporting protocol for Modbus
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for ASI
Supporting protocol for PROFINET IO
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Width
175mm
Height
165mm
Depth
165mm
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
From same serie