![Main Product Image](https://assets.aleta.hr/415x415/5ce643b2-e3ee-454a-bc83-f20c6871bf5c.webp)
![Main Product Image](https://assets.aleta.hr/415x415/5ce643b2-e3ee-454a-bc83-f20c6871bf5c.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Max. output frequency
500Hz
Number of phases output
3
Mains frequency
50/60 Hz
Nominal output current I2N
145A
Max. output voltage
480V
Number of phases input
3
Mains voltage
380 - 480V
Max. output at quadratic load at rated output voltage
75kW
Relative symmetric net frequency tolerance
5%
Number of analogue inputs
3
Application in industrial area permitted
Yes
Supporting protocol for CAN
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for KNX
No
Number of digital outputs
1
Number of analogue outputs
2
Application in domestic- and commercial area permitted
Yes
Supporting protocol for TCP/IP
No
Supporting protocol for ASI
No
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Max. output at linear load at rated output voltage
75kW
Number of digital inputs
8
Supporting protocol for DeviceNet
Yes
With control element
Yes
Relative symmetric net voltage tolerance
10%
Supporting protocol for Data-Highway
No
Supporting protocol for LON
No
Supporting protocol for PROFIBUS
Yes
With optical interface
Yes
With PC connection
No
Integrated breaking resistance
No
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP21
Height
922mm
Width
290mm
Depth
325.5mm
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Supporting protocol for BACnet
No
Number of HW-interfaces RS-485
3
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV930D75N4
![Main Product Image](https://assets.aleta.hr/300x300/b82bd1a1-7512-4c42-91e9-68d0f8d56c37_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Max. output frequency
500Hz
Number of phases output
3
Mains frequency
50/60 Hz
Nominal output current I2N
145A
Max. output voltage
480V
Number of phases input
3
Mains voltage
380 .. 480V
Max. output at quadratic load at rated output voltage
75kW
Relative symmetric net frequency tolerance
5%
Number of analogue inputs
3
Application in industrial area permitted
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for KNX
Number of digital outputs
1
Number of analogue outputs
2
Application in domestic- and commercial area permitted
Supporting protocol for TCP/IP
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for SUCONET
Max. output at linear load at rated output voltage
75kW
Number of digital inputs
8
Supporting protocol for DeviceNet
With control element
Relative symmetric net voltage tolerance
10%
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for PROFIBUS
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP21
Height
922mm
Width
290mm
Depth
325.5mm
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Supporting protocol for BACnet
Number of HW-interfaces RS-485
3
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
From same serie
We use cookies to enhance your experience.