Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
3
Mains voltage
380 - 480V
Max. output frequency
500Hz
Mains frequency
50/60 Hz
Number of phases input
3
Number of analogue outputs
2
Max. output at linear load at rated output voltage
2.2kW
Application in domestic- and commercial area permitted
Yes
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
3
Supporting protocol for ASI
No
Supporting protocol for CAN
No
With control element
Yes
Supporting protocol for PROFIBUS
Yes
Relative symmetric net frequency tolerance
5%
Supporting protocol for KNX
No
Number of digital inputs
6
Nominal output current I2N
5.6A
Max. output voltage
480V
Supporting protocol for SERCOS
No
Max. output at quadratic load at rated output voltage
2.2kW
Supporting protocol for DeviceNet
Yes
Supporting protocol for Modbus
Yes
Supporting protocol for PROFINET IO
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Number of digital outputs
0
Supporting protocol for SUCONET
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for INTERBUS
No
Application in industrial area permitted
Yes
With optical interface
No
Supporting protocol for Foundation Fieldbus
No
With PC connection
No
Integrated breaking resistance
No
Type of converter
U converter
4-quadrant operation possible
Yes
Height
285mm
Width
130mm
Degree of protection (IP)
IP20
Depth
196mm
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Number of HW-interfaces industrial Ethernet
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Supporting protocol for other bus systems
No
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV630U22N4Z
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Number of phases output
3
Mains voltage
380 .. 480V
Max. output frequency
500Hz
Mains frequency
50/60 Hz
Number of phases input
3
Number of analogue outputs
2
Max. output at linear load at rated output voltage
2.2kW
Application in domestic- and commercial area permitted
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
3
Supporting protocol for ASI
Supporting protocol for CAN
With control element
Supporting protocol for PROFIBUS
Relative symmetric net frequency tolerance
5%
Supporting protocol for KNX
Number of digital inputs
6
Nominal output current I2N
5.6A
Max. output voltage
480V
Supporting protocol for SERCOS
Max. output at quadratic load at rated output voltage
2.2kW
Supporting protocol for DeviceNet
Supporting protocol for Modbus
Supporting protocol for PROFINET IO
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Number of digital outputs
0
Supporting protocol for SUCONET
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Application in industrial area permitted
With optical interface
Supporting protocol for Foundation Fieldbus
With PC connection
Integrated breaking resistance
Type of converter
U converter
4-quadrant operation possible
Height
285mm
Width
130mm
Degree of protection (IP)
IP20
Depth
196mm
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Number of HW-interfaces industrial Ethernet
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Supporting protocol for other bus systems
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
0
From same serie
We use cookies to enhance your experience.