![Main Product Image](https://assets.aleta.hr/415x415/4ddd9f63-36f1-4255-97b5-4398f493cc3d.webp)
![Main Product Image](https://assets.aleta.hr/415x415/4ddd9f63-36f1-4255-97b5-4398f493cc3d.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 - 480V
Max. output at linear load at rated output voltage
37kW
Nominal output current I2N
66.2A
Number of phases input
3
Mains frequency
50/60 Hz
Number of analogue inputs
3
Max. output voltage
480V
Max. output at quadratic load at rated output voltage
37kW
Max. output frequency
500Hz
Number of digital outputs
1
Application in industrial area permitted
Yes
With control element
No
Number of analogue outputs
2
Number of digital inputs
8
Relative symmetric net frequency tolerance
5%
Supporting protocol for INTERBUS
No
Number of phases output
3
Supporting protocol for PROFIBUS
No
Supporting protocol for KNX
No
Relative symmetric net voltage tolerance
10%
Supporting protocol for ASI
No
Application in domestic- and commercial area permitted
No
Supporting protocol for CAN
No
Supporting protocol for Modbus
Yes
Supporting protocol for TCP/IP
Yes
With optical interface
No
With PC connection
Yes
4-quadrant operation possible
Yes
Integrated breaking resistance
No
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
1
Width
213mm
Height
660mm
Depth
262mm
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for BACnet
No
Number of HW-interfaces industrial Ethernet
2
Number of HW-interfaces RS-232
0
Supporting protocol for SafetyBUS p
No
Number of interfaces PROFINET
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
1
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV340D30N4E
![Main Product Image](https://assets.aleta.hr/300x300/7bb70bd9-51b9-4c26-9f9c-158b170a4838_optimized.webp)
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
380 .. 480V
Max. output at linear load at rated output voltage
37kW
Nominal output current I2N
66.2A
Number of phases input
3
Mains frequency
50/60 Hz
Number of analogue inputs
3
Max. output voltage
480V
Max. output at quadratic load at rated output voltage
37kW
Max. output frequency
500Hz
Number of digital outputs
1
Application in industrial area permitted
With control element
Number of analogue outputs
2
Number of digital inputs
8
Relative symmetric net frequency tolerance
5%
Supporting protocol for INTERBUS
Number of phases output
3
Supporting protocol for PROFIBUS
Supporting protocol for KNX
Relative symmetric net voltage tolerance
10%
Supporting protocol for ASI
Application in domestic- and commercial area permitted
Supporting protocol for CAN
Supporting protocol for Modbus
Supporting protocol for TCP/IP
With optical interface
With PC connection
4-quadrant operation possible
Integrated breaking resistance
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
1
Width
213mm
Height
660mm
Depth
262mm
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for BACnet
Number of HW-interfaces industrial Ethernet
2
Number of HW-interfaces RS-232
0
Supporting protocol for SafetyBUS p
Number of interfaces PROFINET
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces other
1
From same serie