Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
200 - 240V
Relative symmetric net frequency tolerance
5%
Max. output at linear load at rated output voltage
0.75kW
Number of analogue outputs
1
With control element
Yes
Number of phases output
3
Supporting protocol for INTERBUS
No
Max. output frequency
599Hz
Max. output at quadratic load at rated output voltage
0.75kW
Number of analogue inputs
3
Number of phases input
3
Max. output voltage
240V
Supporting protocol for KNX
No
Supporting protocol for TCP/IP
Yes
Mains frequency
50/60 Hz
Supporting protocol for PROFIBUS
Yes
Number of digital outputs
1
Application in industrial area permitted
Yes
Application in domestic- and commercial area permitted
No
Supporting protocol for CAN
Yes
Relative symmetric net voltage tolerance
10%
Number of digital inputs
6
Supporting protocol for ASI
No
Nominal output current I2N
4.8A
Supporting protocol for PROFINET IO
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SUCONET
No
With optical interface
No
Supporting protocol for Modbus
Yes
With PC connection
Yes
4-quadrant operation possible
Yes
Type of converter
U converter
Integrated breaking resistance
Yes
Degree of protection (IP)
IP20
Degree of protection (NEMA)
1
Width
72mm
Height
143mm
Depth
138mm
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for other bus systems
Yes
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
1
Number of HW-interfaces parallel
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ATV320U07M3C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- SCHNEIDER
Technical specifications
Mains voltage
200 .. 240V
Relative symmetric net frequency tolerance
5%
Max. output at linear load at rated output voltage
0.75kW
Number of analogue outputs
1
With control element
Number of phases output
3
Supporting protocol for INTERBUS
Max. output frequency
599Hz
Max. output at quadratic load at rated output voltage
0.75kW
Number of analogue inputs
3
Number of phases input
3
Max. output voltage
240V
Supporting protocol for KNX
Supporting protocol for TCP/IP
Mains frequency
50/60 Hz
Supporting protocol for PROFIBUS
Number of digital outputs
1
Application in industrial area permitted
Application in domestic- and commercial area permitted
Supporting protocol for CAN
Relative symmetric net voltage tolerance
10%
Number of digital inputs
6
Supporting protocol for ASI
Nominal output current I2N
4.8A
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for SUCONET
With optical interface
Supporting protocol for Modbus
With PC connection
4-quadrant operation possible
Type of converter
U converter
Integrated breaking resistance
Degree of protection (IP)
IP20
Degree of protection (NEMA)
1
Width
72mm
Height
143mm
Depth
138mm
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for other bus systems
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces other
1
Number of HW-interfaces parallel
0
From same serie
We use cookies to enhance your experience.