Details
- Circuit breakers and fuses
- Earth leakage circuit breaker
- 1 KOM
- ABB
Technical specifications
Degree of protection (IP)
IP2X
Voltage type
AC
Built-in depth
68.9mm
Suitable for flush-mounted installation
No
Rated current
6A
Width in number of modular spacings
1
Rated voltage
230V
Release characteristic
B
Number of protected poles
1
Over voltage category
3
Number of poles (total)
2
Current limiting class
3
Pollution degree
2
Concurrently switching neutral conductor
No
Frequency
50/60 Hz
Leakage current type
A
Surge current capacity
0.25kA
Rated fault current
0.03A
Anti-nuisance tripping version
No
Rated short-circuit breaking capacity according to IEC 60947-2
6kA
Rated short-circuit breaking capacity according to EN 60898
6kA
Rated insulation voltage Ui
500V
Rated impulse withstand voltage Uimp
4kV
Power loss
2.5W
Rated short-circuit breaking capacity according to EN 61009
6kA
Rated short-circuit breaking capacity Icn according to EN 61009-1
6kA
Disconnection characteristic
Undelayed
With interlocking device
Yes
Ambient temperature during operating
-25 - 55°C
Flush-mounted installation
No
Connectable conductor cross section solid-core
1 - 25mm²
Connectable conductor cross section multi-wired
1 - 16mm²
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
2CSR255151R1065 | DSE201 B6 A30

Details
- Circuit breakers and fuses
- Earth leakage circuit breaker
- 1 KOM
- ABB
Technical specifications
Degree of protection (IP)
IP2X
Voltage type
AC
Built-in depth
68.9mm
Suitable for flush-mounted installation
Rated current
6A
Width in number of modular spacings
1
Rated voltage
230V
Release characteristic
B
Number of protected poles
1
Over voltage category
3
Number of poles (total)
2
Current limiting class
3
Pollution degree
2
Concurrently switching neutral conductor
Frequency
50/60 Hz
Leakage current type
A
Surge current capacity
0.25kA
Rated fault current
0.03A
Anti-nuisance tripping version
Rated short-circuit breaking capacity according to IEC 60947-2
6kA
Rated short-circuit breaking capacity according to EN 60898
6kA
Rated insulation voltage Ui
500V
Rated impulse withstand voltage Uimp
4kV
Power loss
2.5W
Rated short-circuit breaking capacity according to EN 61009
6kA
Rated short-circuit breaking capacity Icn according to EN 61009-1
6kA
Disconnection characteristic
Undelayed
With interlocking device
Ambient temperature during operating
-25 .. 55°C
Flush-mounted installation
Connectable conductor cross section solid-core
1 .. 25mm²
Connectable conductor cross section multi-wired
1 .. 16mm²
From same serie