Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- ABB
Technical specifications
Degree of protection (IP)
IP20
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
3 modular spacing
Max. continuous voltage AC
760V
Signalling at the device
Optic
Number of conductors (without earthing)
3
Max. continuous voltage DC
-V
Voltage protection level
2.9kV
Nominal voltage AC
690V
Voltage protection level L-N
2.9kV
Max. conductor cross section flexible (fine-strand)
16mm²
Max. conductor cross section solid (solid, stranded)
25mm²
Integrated backup fuse
Yes
Nominal voltage DC
-V
With remote signalling contact
No
Voltage protection level N-PE
2.9kV
Nominal discharge surge current (8/20)
15kA
System configuration DC
No
System configuration TN
Yes
System configuration IT
Yes
System configuration TN-S
No
System configuration TT
No
System configuration TN-C-S
No
System configuration TN-C
Yes
System configuration other
No
Max. PV-voltage
-V
Category type 2
Yes
Max. discharge surge current (8/20)
120kA
Short-circuit breaking capacity (Isccr)
50kA
Max. overcurrent protection device, series connection (fuse)
50A
Leakage-current free
No
Integrated short-circuit protection selective to fuse gG
50A
Max. overcurrent protection device, parallel connection (fuse)
-A
Integrated short-circuit protection
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
2CTB803853R4500 | OVR T2 3L 40-400/690 P

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- ABB
Technical specifications
Degree of protection (IP)
IP20
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
3 modular spacing
Max. continuous voltage AC
760V
Signalling at the device
Optic
Number of conductors (without earthing)
3
Max. continuous voltage DC
-V
Voltage protection level
2.9kV
Nominal voltage AC
690V
Voltage protection level L-N
2.9kV
Max. conductor cross section flexible (fine-strand)
16mm²
Max. conductor cross section solid (solid, stranded)
25mm²
Integrated backup fuse
Nominal voltage DC
-V
With remote signalling contact
Voltage protection level N-PE
2.9kV
Nominal discharge surge current (8/20)
15kA
System configuration DC
System configuration TN
System configuration IT
System configuration TN-S
System configuration TT
System configuration TN-C-S
System configuration TN-C
System configuration other
Max. PV-voltage
-V
Category type 2
Max. discharge surge current (8/20)
120kA
Short-circuit breaking capacity (Isccr)
50kA
Max. overcurrent protection device, series connection (fuse)
50A
Leakage-current free
Integrated short-circuit protection selective to fuse gG
50A
Max. overcurrent protection device, parallel connection (fuse)
-A
Integrated short-circuit protection
From same serie
We use cookies to enhance your experience.