Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
400.0 - 1000A
Integrated earth fault protection
Yes
Rated permanent current Iu
1000A
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
No
Type of electrical connection of main circuit
Bolt connection
With integrated under voltage release
No
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
Motor drive optional
Yes
DIN rail (top hat rail) mounting optional
Yes
Rated voltage
220 - 690V
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Degree of protection (IP)
IP20
Number of auxiliary contacts as normally closed contact
0
Type of control element
Toggle
Position of connection for main current circuit
Front side
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA101799R1 | XT7L M 1000 Ekip Hi-Touch LSIG 1

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
400.0 .. 1000A
Integrated earth fault protection
Rated permanent current Iu
1000A
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as change-over contact
0
With switched-off indicator
Type of electrical connection of main circuit
Bolt connection
With integrated under voltage release
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Motor drive optional
DIN rail (top hat rail) mounting optional
Rated voltage
220 .. 690V
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Degree of protection (IP)
IP20
Number of auxiliary contacts as normally closed contact
0
Type of control element
Toggle
Position of connection for main current circuit
Front side
Motor drive integrated
From same serie