Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
220 - 690V
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
With integrated under voltage release
No
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Complete device with protection unit
Yes
Overload release current setting
400.0 - 1000A
Rated permanent current Iu
1000A
Type of control element
Toggle
Degree of protection (IP)
IP20
DIN rail (top hat rail) mounting optional
Yes
Motor drive optional
Yes
Motor drive integrated
No
With switched-off indicator
No
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Position of connection for main current circuit
Front side
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA101795R1 | XT7L M 1000 Ekip Hi-Touch LSI 10

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
220 .. 690V
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Integrated earth fault protection
Type of electrical connection of main circuit
Bolt connection
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
With integrated under voltage release
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Number of poles
4
Complete device with protection unit
Overload release current setting
400.0 .. 1000A
Rated permanent current Iu
1000A
Type of control element
Toggle
Degree of protection (IP)
IP20
DIN rail (top hat rail) mounting optional
Motor drive optional
Motor drive integrated
With switched-off indicator
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Position of connection for main current circuit
Front side
From same serie