Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
220 - 690V
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Overload release current setting
400.0 - 1000A
Rated permanent current Iu
1000A
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
Yes
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Bolt connection
Position of connection for main current circuit
Front side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
3
With switched-off indicator
No
Type of control element
Toggle
Motor drive integrated
No
Degree of protection (IP)
IP20
Complete device with protection unit
Yes
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Yes
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA101519R1 | XT7L M 1000 EkipTouchMeas.LSIG 1

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
220 .. 690V
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Overload release current setting
400.0 .. 1000A
Rated permanent current Iu
1000A
Device construction
Built-in device fixed built-in technique
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Bolt connection
Position of connection for main current circuit
Front side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
Number of poles
3
With switched-off indicator
Type of control element
Toggle
Motor drive integrated
Degree of protection (IP)
IP20
Complete device with protection unit
Motor drive optional
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
From same serie