Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
500.0 - 1250A
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
Integrated earth fault protection
No
Adjustment range undelayed short-circuit release
1250 - 12500A
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range short-term delayed short-circuit release
1250 - 12500A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
DIN rail (top hat rail) mounting optional
Yes
Type of control element
Toggle
Position of connection for main current circuit
Front side
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
With integrated under voltage release
No
With switched-off indicator
No
Number of poles
3
Rated voltage
220 - 690V
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA101500R1 | XT7L M 1250 Ekip Dip LSI In=1250

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
500.0 .. 1250A
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
120kA
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1250 .. 12500A
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Adjustment range short-term delayed short-circuit release
1250 .. 12500A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
DIN rail (top hat rail) mounting optional
Type of control element
Toggle
Position of connection for main current circuit
Front side
Complete device with protection unit
Motor drive integrated
Motor drive optional
With integrated under voltage release
With switched-off indicator
Number of poles
3
Rated voltage
220 .. 690V
Degree of protection (IP)
IP20
From same serie