Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
220 - 690V
Overload release current setting
500.0 - 1250A
Rated permanent current Iu
1250A
Adjustment range short-term delayed short-circuit release
1250 - 12500A
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
1250 - 12500A
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Yes
With integrated under voltage release
No
With switched-off indicator
No
Number of auxiliary contacts as change-over contact
0
Number of poles
3
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Motor drive optional
Yes
Motor drive integrated
No
Type of control element
Toggle
Degree of protection (IP)
IP20
Complete device with protection unit
Yes
Position of connection for main current circuit
Front side
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA101440R1 | XT7H M 1250 Ekip Dip LSIG In1250

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
220 .. 690V
Overload release current setting
500.0 .. 1250A
Rated permanent current Iu
1250A
Adjustment range short-term delayed short-circuit release
1250 .. 12500A
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1250 .. 12500A
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
With integrated under voltage release
With switched-off indicator
Number of auxiliary contacts as change-over contact
0
Number of poles
3
Type of electrical connection of main circuit
Bolt connection
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Motor drive optional
Motor drive integrated
Type of control element
Toggle
Degree of protection (IP)
IP20
Complete device with protection unit
Position of connection for main current circuit
Front side
From same serie