Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Rated permanent current Iu
1000A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
DIN rail (top hat rail) mounting optional
Yes
Integrated earth fault protection
No
Rated voltage
220 - 690V
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
400.0 - 1000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
No
Motor drive integrated
No
Complete device with protection unit
Yes
Position of connection for main current circuit
Front side
Motor drive optional
Yes
Degree of protection (IP)
IP20
Type of control element
Toggle
With integrated under voltage release
No
Number of poles
3
Number of auxiliary contacts as change-over contact
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA101395R1 | XT7S M 1000 Ekip Hi-Touch LSI 10

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Rated permanent current Iu
1000A
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Rated voltage
220 .. 690V
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
400.0 .. 1000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Motor drive integrated
Complete device with protection unit
Position of connection for main current circuit
Front side
Motor drive optional
Degree of protection (IP)
IP20
Type of control element
Toggle
With integrated under voltage release
Number of poles
3