Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range short-term delayed short-circuit release
1000 - 10000A
Integrated earth fault protection
No
Adjustment range undelayed short-circuit release
1000 - 10000A
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device fixed built-in technique
With integrated under voltage release
No
With switched-off indicator
No
Number of auxiliary contacts as normally open contact
0
Rated voltage
220 - 690V
Number of auxiliary contacts as change-over contact
0
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
400.0 - 1000A
Position of connection for main current circuit
Front side
Suitable for DIN rail (top hat rail) mounting
No
Type of control element
Toggle
DIN rail (top hat rail) mounting optional
Yes
Complete device with protection unit
Yes
Motor drive integrated
No
Degree of protection (IP)
IP20
Number of poles
3
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA101367R1 | XT7S M 1000 Ekip Dip LS/I In1000
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range short-term delayed short-circuit release
1000 .. 10000A
Integrated earth fault protection
Adjustment range undelayed short-circuit release
1000 .. 10000A
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device fixed built-in technique
With integrated under voltage release
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Rated voltage
220 .. 690V
Number of auxiliary contacts as change-over contact
0
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
400.0 .. 1000A
Position of connection for main current circuit
Front side
Suitable for DIN rail (top hat rail) mounting
Type of control element
Toggle
DIN rail (top hat rail) mounting optional
Complete device with protection unit
Motor drive integrated
Degree of protection (IP)
IP20
Number of poles
3
Motor drive optional
From same serie