Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Adjustment range short-term delayed short-circuit release
750.0 - 12500A
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Rated voltage
220 - 690V
Overload release current setting
500.0 - 1250A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Yes
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
Yes
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
Type of control element
Toggle
Number of poles
3
Motor drive optional
Yes
Motor drive integrated
No
With switched-off indicator
No
With integrated under voltage release
No
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP20
Suitable for DIN rail (top hat rail) mounting
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA100916R1 | XT7H 1250 Ekip Touch Meas.LSIG 1

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Adjustment range short-term delayed short-circuit release
750.0 .. 12500A
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
70kA
Rated voltage
220 .. 690V
Overload release current setting
500.0 .. 1250A
Type of electrical connection of main circuit
Bolt connection
Integrated earth fault protection
Device construction
Built-in device fixed built-in technique
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Type of control element
Toggle
Number of poles
3
Motor drive optional
Motor drive integrated
With switched-off indicator
With integrated under voltage release
Position of connection for main current circuit
Front side
Degree of protection (IP)
IP20
Suitable for DIN rail (top hat rail) mounting
From same serie