Technical specifications
Number of phases output
3
Max. output frequency
500Hz
Max. output at quadratic load at rated output voltage
3kW
Number of phases input
3
Max. output voltage
480V
Relative symmetric net frequency tolerance
5%
Number of analogue inputs
2
Number of digital inputs
6
Mains frequency
50/60 Hz
Max. output at linear load at rated output voltage
3kW
Application in industrial area permitted
Yes
Relative symmetric net voltage tolerance
10%
Mains voltage
380 - 480V
With control element
Yes
Nominal output current I2N
7.2A
Number of digital outputs
3
Number of analogue outputs
2
Supporting protocol for TCP/IP
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFIsafe
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for KNX
No
Supporting protocol for LON
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Modbus
Yes
Supporting protocol for DeviceNet Safety
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for ASI
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for CAN
Yes
Number of HW-interfaces RS-422
0
Supporting protocol for BACnet
No
Height
373mm
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Supporting protocol for other bus systems
Yes
With optical interface
No
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
2
Number of HW-interfaces RS-232
0
Number of HW-interfaces other
2
Width
125mm
Degree of protection (IP)
IP21
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
1
4-quadrant operation possible
No
Type of converter
U converter
Integrated breaking resistance
No
Degree of protection (NEMA)
1
With PC connection
Yes
Depth
223mm
Warehouse states
Zagreb:
1 pcs
Zadar:
0 pcs
From same serie
ACS580-01-07A3-4 +J400 | ACS580-01-07A3-4 +J400

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- ABB
Technical specifications
Number of phases output
3
Max. output frequency
500Hz
Max. output at quadratic load at rated output voltage
3kW
Number of phases input
3
Max. output voltage
480V
Relative symmetric net frequency tolerance
5%
Number of analogue inputs
2
Number of digital inputs
6
Mains frequency
50/60 Hz
Max. output at linear load at rated output voltage
3kW
Application in industrial area permitted
Relative symmetric net voltage tolerance
10%
Mains voltage
380 .. 480V
With control element
Nominal output current I2N
7.2A
Number of digital outputs
3
Number of analogue outputs
2
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for PROFIsafe
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Supporting protocol for KNX
Supporting protocol for LON
Supporting protocol for PROFIBUS
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Modbus
Supporting protocol for DeviceNet Safety
Application in domestic- and commercial area permitted
Supporting protocol for ASI
Supporting protocol for INTERBUS-Safety
Supporting protocol for CAN
Number of HW-interfaces RS-422
0
Supporting protocol for BACnet
Height
373mm
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Supporting protocol for other bus systems
With optical interface
Supporting protocol for SafetyBUS p
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
2
Number of HW-interfaces RS-232
0
Number of HW-interfaces other
2
Width
125mm
Degree of protection (IP)
IP21
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
1
4-quadrant operation possible
Type of converter
U converter
Integrated breaking resistance
Degree of protection (NEMA)
1
With PC connection
Depth
223mm
From same serie