Aleta.hr
Main Product Image

2CDS253025R0164 | SZ203-C16

Code: 1885800

ManufacturerRAZNO
Catalog number2CDS253025R0164
Type
EAN code4053546038972

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Built-in depth

69mm

Number of protected poles

3

Rated current

16A

Rated insulation voltage Ui

440V

Number of poles (total)

3

Power loss

-W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 - 60Hz

Over voltage category

3

Flush-mounted installation

No

Additional equipment possible

Yes

Width in number of modular spacings

3.0

Connectable conductor cross section solid-core

0.75 - 35mm²

Ambient temperature during operating

-25 - 55°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 - 25mm²

Explosion-proof

No

Concurrently switching neutral conductor

No

Pollution degree

2


Warehouse states

Zagreb:

110 pcs

Zadar:

15 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS253025R0164 | SZ203-C16

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Rated voltage

400V

Rated impulse withstand voltage Uimp

4kV

Voltage type

Other

Built-in depth

69mm

Number of protected poles

3

Rated current

16A

Rated insulation voltage Ui

440V

Number of poles (total)

3

Power loss

-W

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Over voltage category

3

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

3.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Concurrently switching neutral conductor

Pollution degree

2

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.