Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - power supply/segment module
- 1 KOM
- EATON
Technical specifications
Supply voltage AC 50 Hz
0 - 0V
Voltage type of supply voltage
AC
Number of HW-interfaces industrial Ethernet
0
Supply voltage DC
102 - 253V
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces other
1
With optical interface
No
Supporting protocol for EtherCAT
No
Supporting protocol for CAN
No
Supporting protocol for TCP/IP
No
Supporting protocol for INTERBUS
No
Supply voltage AC 60 Hz
0 - 0V
Number of interfaces PROFINET
0
Supporting protocol for PROFIBUS
No
Fieldbus connection over separate bus coupler possible
Yes
Bus diagnosis possible
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
No
Front built-in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Width
12.6mm
Height
74.1mm
Depth
55.4mm
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet Safety
No
Radio standard Bluetooth
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Radio standard Wi-Fi 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
System accessory
Yes
Radio standard UMTS
No
Degree of protection (IP)
IP20
Type of electric connection
Screw-/spring clamp connection
With potential separation
Yes
Suitable as segment module
Yes
With power supply module
No
Remote module
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XN-PF-120/230VAC-D

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - power supply/segment module
- 1 KOM
- EATON
Technical specifications
Supply voltage AC 50 Hz
0 .. 0V
Voltage type of supply voltage
AC
Number of HW-interfaces industrial Ethernet
0
Supply voltage DC
102 .. 253V
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces Wireless
0
Number of HW-interfaces other
1
With optical interface
Supporting protocol for EtherCAT
Supporting protocol for CAN
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supply voltage AC 60 Hz
0 .. 0V
Number of interfaces PROFINET
0
Supporting protocol for PROFIBUS
Fieldbus connection over separate bus coupler possible
Bus diagnosis possible
Rail mounting possible
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
Suitable for safety functions
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Width
12.6mm
Height
74.1mm
Depth
55.4mm
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Radio standard Bluetooth
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Radio standard Wi-Fi 802.11
Radio standard GPRS
Radio standard GSM
System accessory
Radio standard UMTS
Degree of protection (IP)
IP20
Type of electric connection
Screw-/spring clamp connection
With potential separation
Suitable as segment module
With power supply module
Remote module
From same serie