Aleta.hr

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • EATON

Technical specifications

Input, voltage

Yes

Voltage type of supply voltage

DC

Input, resistance thermometer

Yes

Input, resistor

Yes

Supply voltage DC

20.4 - 28.8V

Resolution of the analogue outputs

0Bit

Input signal, configurable

Yes

Resolution of the analogue inputs

16Bit

Analogue outputs configurable

Yes

Output signal configurable

No

Supply voltage AC 50 Hz

0 - 0V

Number of HW-interfaces RS-422

0

Number of interfaces PROFINET

0

Number of HW-interfaces parallel

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-485

0

Output, current

No

Number of analogue outputs

0

Input, thermocouple

No

Supporting protocol for TCP/IP

No

Number of HW-interfaces Wireless

0

Number of HW-interfaces USB

0

Supply voltage AC 60 Hz

0 - 0V

Supporting protocol for Modbus

No

Analogue inputs configurable

Yes

Supporting protocol for PROFIBUS

No

Output, voltage

No

Supporting protocol for CAN

No

Supporting protocol for ASI

No

Supporting protocol for EtherCAT

No

Supporting protocol for KNX

No

Supporting protocol for Data-Highway

No

Supporting protocol for INTERBUS

No

Number of HW-interfaces other

1

Input, current

Yes

Supporting protocol for DeviceNet

No

Number of HW-interfaces serial TTY

0

Number of analogue inputs

8

Number of HW-interfaces RS-232

0

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

Yes

Radio standard Wi-Fi 802.11

No

Radio standard Bluetooth

No

Radio standard GPRS

No

Radio standard GSM

No

Radio standard UMTS

No

System accessory

Yes

Degree of protection (NEMA)

1

Degree of protection (IP)

IP20

Type of electric connection

Plug-in connection

Fieldbus connection over separate bus coupler possible

Yes

Wall mounting/direct mounting

No

Rail mounting possible

Yes

IO link master

No

Front built-in possible

No

Rack-assembly possible

No

Suitable for safety functions

No

SIL according to IEC 61508

None

Appendant operation agent (Ex ia)

No

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ib)

No

Explosion safety category for gas

None

Explosion safety category for dust

None

Certified for UL hazardous location class I

No

Certified for UL hazardous location class II

No

Certified for UL hazardous location class III

No

Certified for UL hazardous location division 1

No

Certified for UL hazardous location division 2

No

Certified for UL hazardous location group A (acetylene)

No

Certified for UL hazardous location group B (hydrogen)

No

Certified for UL hazardous location group C (ethylene)

No

Certified for UL hazardous location group D (propane)

No

Certified for UL hazardous location group E (metal dusts)

No

Certified for UL hazardous location group F (carbonaceous dusts)

No

Certified for UL hazardous location group G (non-conductive dusts)

No

Height

74.5mm

Width

13mm

Depth

161.5mm

Supporting protocol for LON

No

Supporting protocol for SUCONET

No

Supporting protocol for PROFINET IO

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for SERCOS

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XNE-8AI-U/I-4PT/NI

Main Product Image

Details

  • Programmable logic controllers PLC
  • Fieldbus, decentr. periphery - analogue I/O module
  • 1 KOM
  • EATON

Technical specifications

Input, voltage

Voltage type of supply voltage

DC

Input, resistance thermometer

Input, resistor

Supply voltage DC

20.4 .. 28.8V

Resolution of the analogue outputs

0Bit

Input signal, configurable

Resolution of the analogue inputs

16Bit

Analogue outputs configurable

Output signal configurable

Supply voltage AC 50 Hz

0 .. 0V

Number of HW-interfaces RS-422

0

Number of interfaces PROFINET

0

Number of HW-interfaces parallel

0

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-485

0

Output, current

Number of analogue outputs

0

Input, thermocouple

Supporting protocol for TCP/IP

Number of HW-interfaces Wireless

0

Number of HW-interfaces USB

0

Supply voltage AC 60 Hz

0 .. 0V

Supporting protocol for Modbus

Analogue inputs configurable

Supporting protocol for PROFIBUS

Output, voltage

Supporting protocol for CAN

Supporting protocol for ASI

Supporting protocol for EtherCAT

Supporting protocol for KNX

Supporting protocol for Data-Highway

Supporting protocol for INTERBUS

Number of HW-interfaces other

1

Input, current

Supporting protocol for DeviceNet

Number of HW-interfaces serial TTY

0

Number of analogue inputs

8

Number of HW-interfaces RS-232

0

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Radio standard Wi-Fi 802.11

Radio standard Bluetooth

Radio standard GPRS

Radio standard GSM

Radio standard UMTS

System accessory

Degree of protection (NEMA)

1

Degree of protection (IP)

IP20

Type of electric connection

Plug-in connection

Fieldbus connection over separate bus coupler possible

Wall mounting/direct mounting

Rail mounting possible

IO link master

Front built-in possible

Rack-assembly possible

Suitable for safety functions

SIL according to IEC 61508

None

Appendant operation agent (Ex ia)

Performance level according to EN ISO 13849-1

None

Appendant operation agent (Ex ib)

Explosion safety category for gas

None

Explosion safety category for dust

None

Certified for UL hazardous location class I

Certified for UL hazardous location class II

Certified for UL hazardous location class III

Certified for UL hazardous location division 1

Certified for UL hazardous location division 2

Certified for UL hazardous location group A (acetylene)

Certified for UL hazardous location group B (hydrogen)

Certified for UL hazardous location group C (ethylene)

Certified for UL hazardous location group D (propane)

Certified for UL hazardous location group E (metal dusts)

Certified for UL hazardous location group F (carbonaceous dusts)

Certified for UL hazardous location group G (non-conductive dusts)

Height

74.5mm

Width

13mm

Depth

161.5mm

Supporting protocol for LON

Supporting protocol for SUCONET

Supporting protocol for PROFINET IO

Supporting protocol for PROFINET CBA

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

From same serie