Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP20
Width
12.6mm
Depth
55.4mm
Height
74.1mm
Type of electric connection
Plug-in connection
Suitable for safety functions
No
Explosion safety category for dust
None
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for EtherNet/IP
No
Supporting protocol for ASI
No
Supporting protocol for TCP/IP
No
Supporting protocol for CAN
Yes
Supporting protocol for PROFIBUS
Yes
Performance level according to EN ISO 13849-1
None
Supporting protocol for INTERBUS
No
SIL according to IEC 61508
None
Supporting protocol for KNX
No
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Category according to EN 954-1
None
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Number of HW-interfaces other
1
Number of HW-interfaces industrial Ethernet
0
Explosion safety category for gas
None
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for other bus systems
Yes
Supporting protocol for Data-Highway
No
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
With optical interface
No
Number of digital inputs
0
Number of digital outputs
32
Voltage type of supply voltage
DC
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Supply voltage DC
18 - 30V
Supply voltage AC 60 Hz
0 - 0V
Supply voltage AC 50 Hz
0 - 0V
Wall mounting/direct mounting
No
Radio standard GSM
No
Radio standard UMTS
No
IO link master
No
Radio standard GPRS
No
Radio standard Bluetooth
No
Radio standard Wi-Fi 802.11
No
Number of HW-interfaces Wireless
0
Front built-in possible
No
Rack-assembly possible
No
Rail mounting possible
Yes
System accessory
Yes
Type of voltage (input voltage)
DC
Type of output voltage
DC
Output current
0.5A
Time delay at signal exchange
0 - 0.3ms
Short-circuit protection, outputs available
Yes
Permitted voltage at input
0 - 0V
Permitted voltage at output
0 - 29V
Digital inputs configurable
No
Input current at signal 1
0mA
Digital outputs configurable
No
Fieldbus connection over separate bus coupler possible
Yes
Type of digital output
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XN-32DO-24VDC-0.5A-P

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - digital I/O module
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP20
Width
12.6mm
Depth
55.4mm
Height
74.1mm
Type of electric connection
Plug-in connection
Suitable for safety functions
Explosion safety category for dust
None
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for EtherNet/IP
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Performance level according to EN ISO 13849-1
None
Supporting protocol for INTERBUS
SIL according to IEC 61508
None
Supporting protocol for KNX
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Category according to EN 954-1
None
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Number of HW-interfaces other
1
Number of HW-interfaces industrial Ethernet
0
Explosion safety category for gas
None
Supporting protocol for PROFINET IO
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for PROFINET CBA
Supporting protocol for other bus systems
Supporting protocol for Data-Highway
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces serial TTY
0
With optical interface
Number of digital inputs
0
Number of digital outputs
32
Voltage type of supply voltage
DC
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Supply voltage DC
18 .. 30V
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage AC 50 Hz
0 .. 0V
Wall mounting/direct mounting
Radio standard GSM
Radio standard UMTS
IO link master
Radio standard GPRS
Radio standard Bluetooth
Radio standard Wi-Fi 802.11
Number of HW-interfaces Wireless
0
Front built-in possible
Rack-assembly possible
Rail mounting possible
System accessory
Type of voltage (input voltage)
DC
Type of output voltage
DC
Output current
0.5A
Time delay at signal exchange
0 .. 0.3ms
Short-circuit protection, outputs available
Permitted voltage at input
0 .. 0V
Permitted voltage at output
0 .. 29V
Digital inputs configurable
Input current at signal 1
0mA
Digital outputs configurable
Fieldbus connection over separate bus coupler possible
Type of digital output
Other
From same serie
We use cookies to enhance your experience.