Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - power supply/segment module
- 1 KOM
- EATON
Technical specifications
Supply voltage AC 60 Hz
0 - 0V
Supply voltage AC 50 Hz
0 - 0V
Voltage type of supply voltage
DC
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Supporting protocol for PROFIBUS
No
Supporting protocol for EtherCAT
No
Supporting protocol for TCP/IP
No
Number of HW-interfaces USB
0
Supporting protocol for CAN
No
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Number of HW-interfaces Wireless
0
Supply voltage DC
18 - 30V
Supporting protocol for INTERBUS
No
With optical interface
No
Supporting protocol for Modbus
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET IO
No
Number of HW-interfaces RS-485
0
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Number of HW-interfaces serial TTY
0
Supporting protocol for PROFINET CBA
No
Number of HW-interfaces other
1
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Radio standard UMTS
No
Supporting protocol for other bus systems
No
Radio standard Wi-Fi 802.11
No
Radio standard GPRS
No
Radio standard GSM
No
Degree of protection (IP)
IP20
Remote module
No
Type of electric connection
Plug-in connection
System accessory
Yes
With power supply module
No
Suitable as segment module
No
With potential separation
No
Radio standard Bluetooth
No
Fieldbus connection over separate bus coupler possible
Yes
Bus diagnosis possible
No
Rail mounting possible
Yes
Wall mounting/direct mounting
No
Front built-in possible
No
Rack-assembly possible
No
Suitable for safety functions
No
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ib)
No
Appendant operation agent (Ex ia)
No
Supporting protocol for DeviceNet Safety
No
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Width
80.3mm
Height
16.8mm
Depth
104.2mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XN-322-4PS-20

Details
- Programmable logic controllers PLC
- Fieldbus, decentr. periphery - power supply/segment module
- 1 KOM
- EATON
Technical specifications
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage AC 50 Hz
0 .. 0V
Voltage type of supply voltage
DC
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Supporting protocol for PROFIBUS
Supporting protocol for EtherCAT
Supporting protocol for TCP/IP
Number of HW-interfaces USB
0
Supporting protocol for CAN
Supporting protocol for ASI
Supporting protocol for KNX
Number of HW-interfaces Wireless
0
Supply voltage DC
18 .. 30V
Supporting protocol for INTERBUS
With optical interface
Supporting protocol for Modbus
Supporting protocol for LON
Supporting protocol for DeviceNet
Supporting protocol for PROFINET IO
Number of HW-interfaces RS-485
0
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Number of HW-interfaces serial TTY
0
Supporting protocol for PROFINET CBA
Number of HW-interfaces other
1
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Radio standard UMTS
Supporting protocol for other bus systems
Radio standard Wi-Fi 802.11
Radio standard GPRS
Radio standard GSM
Degree of protection (IP)
IP20
Remote module
Type of electric connection
Plug-in connection
System accessory
With power supply module
Suitable as segment module
With potential separation
Radio standard Bluetooth
Fieldbus connection over separate bus coupler possible
Bus diagnosis possible
Rail mounting possible
Wall mounting/direct mounting
Front built-in possible
Rack-assembly possible
Suitable for safety functions
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ib)
Appendant operation agent (Ex ia)
Supporting protocol for DeviceNet Safety
Explosion safety category for gas
None
Explosion safety category for dust
None
Certified for UL hazardous location class I
Certified for UL hazardous location class II
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location class III
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Width
80.3mm
Height
16.8mm
Depth
104.2mm
From same serie
We use cookies to enhance your experience.