Technical specifications
Number of HW-interfaces RS-422
0
Supply voltage AC 50 Hz
0 - 0V
Number of HW-interfaces industrial Ethernet
0
Supply voltage DC
20.4 - 28.8V
Number of HW-interfaces RS-485
1
Supply voltage AC 60 Hz
0 - 0V
Number of relay outputs
0
Processing time (1K, binary operation)
0.5ms
Number of HW-interfaces RS-232
1
Number of HW-interfaces other
1
Model
Modular
Voltage type of supply voltage
DC
Supporting protocol for EtherCAT
No
Supporting protocol for INTERBUS
No
Supporting protocol for CAN
Yes
Supporting protocol for ASI
No
Number of analogue outputs
0
Number of analogue inputs
0
With optical interface
No
Supporting protocol for KNX
No
Number of HW-interfaces USB
0
Number of digital outputs
8
Number of HW-interfaces parallel
0
Number of digital inputs
18
Number of HW-interfaces Wireless
0
Supporting protocol for Modbus
Yes
Supporting protocol for TCP/IP
No
Number of interfaces PROFINET
0
Supporting protocol for DeviceNet
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for SafetyBUS p
No
Supporting protocol for IEC 61850 Ethernet
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DNP3
No
Supporting protocol for IEC 60870
No
Supporting protocol for PROFIsafe
No
Radio standard Wi-Fi 802.11
No
Radio standard Bluetooth
No
Supporting protocol for SERCOS
No
Supporting protocol for other bus systems
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
Yes
Supporting protocol for AS-Interface Safety at Work
No
Max. number of time switches
1000
Radio standard GPRS
No
Radio standard GSM
No
Long-Term Evolution (LTE)
No
Radio standard UMTS
No
System accessory
Yes
IO link master
No
With display
No
Memory size
256kByte
Type of memory
RAM
Rail mounting possible
Yes
Additional program memory possible
Yes
Redundancy
No
Wall mounting/direct mounting
Yes
Rack-assembly possible
No
SIL according to IEC 61508
None
Suitable for safety functions
No
Appendant operation agent (Ex ia)
No
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ib)
No
Certified for UL hazardous location class I
No
Explosion safety category for dust
None
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location class III
No
Explosion safety category for gas
None
Certified for UL hazardous location division 1
No
Front built-in possible
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Width
60mm
Depth
100mm
Height
100mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
XC-CPU121-2C256K

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- EATON
Technical specifications
Number of HW-interfaces RS-422
0
Supply voltage AC 50 Hz
0 .. 0V
Number of HW-interfaces industrial Ethernet
0
Supply voltage DC
20.4 .. 28.8V
Number of HW-interfaces RS-485
1
Supply voltage AC 60 Hz
0 .. 0V
Number of relay outputs
0
Processing time (1K, binary operation)
0.5ms
Number of HW-interfaces RS-232
1
Number of HW-interfaces other
1
Model
Modular
Voltage type of supply voltage
DC
Supporting protocol for EtherCAT
Supporting protocol for INTERBUS
Supporting protocol for CAN
Supporting protocol for ASI
Number of analogue outputs
0
Number of analogue inputs
0
With optical interface
Supporting protocol for KNX
Number of HW-interfaces USB
0
Number of digital outputs
8
Number of HW-interfaces parallel
0
Number of digital inputs
18
Number of HW-interfaces Wireless
0
Supporting protocol for Modbus
Supporting protocol for TCP/IP
Number of interfaces PROFINET
0
Supporting protocol for DeviceNet
Supporting protocol for EtherNet/IP
Supporting protocol for LON
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFINET IO
Supporting protocol for PROFIBUS
Supporting protocol for SafetyBUS p
Supporting protocol for IEC 61850 Ethernet
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS-Safety
Supporting protocol for DNP3
Supporting protocol for IEC 60870
Supporting protocol for PROFIsafe
Radio standard Wi-Fi 802.11
Radio standard Bluetooth
Supporting protocol for SERCOS
Supporting protocol for other bus systems
Supporting protocol for PROFINET CBA
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for AS-Interface Safety at Work
Max. number of time switches
1000
Radio standard GPRS
Radio standard GSM
Long-Term Evolution (LTE)
Radio standard UMTS
System accessory
IO link master
With display
Memory size
256kByte
Type of memory
RAM
Rail mounting possible
Additional program memory possible
Redundancy
Wall mounting/direct mounting
Rack-assembly possible
SIL according to IEC 61508
None
Suitable for safety functions
Appendant operation agent (Ex ia)
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ib)
Certified for UL hazardous location class I
Explosion safety category for dust
None
Certified for UL hazardous location division 2
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location class II
Certified for UL hazardous location class III
Explosion safety category for gas
None
Certified for UL hazardous location division 1
Front built-in possible
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group G (non-conductive dusts)