

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- EATON
Technical specifications
Voltage type of supply voltage
DC
Supply voltage AC 60 Hz
0 - 0V
Number of relay outputs
0
Supply voltage DC
20.4 - 28.8V
Max. number of time switches
1000
Number of HW-interfaces industrial Ethernet
0
Processing time (1K, binary operation)
0.5ms
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
1
Number of analogue outputs
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Number of analogue inputs
0
Number of HW-interfaces other
1
Number of digital inputs
8
Number of HW-interfaces RS-485
0
Supporting protocol for TCP/IP
No
Number of digital outputs
6
Supporting protocol for INTERBUS
No
Supply voltage AC 50 Hz
0 - 0V
Supporting protocol for KNX
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
With optical interface
Yes
Number of HW-interfaces Wireless
0
Supporting protocol for ASI
No
Supporting protocol for Modbus
Yes
Supporting protocol for EtherCAT
No
Model
Modular
Radio standard GPRS
No
Radio standard GSM
No
Radio standard UMTS
No
Long-Term Evolution (LTE)
No
System accessory
Yes
Redundancy
No
With display
No
Type of memory
RAM
IO link master
No
Memory size
128kByte
Additional program memory possible
Yes
Wall mounting/direct mounting
Yes
Rail mounting possible
Yes
Front built-in possible
No
Rack-assembly possible
Yes
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
Appendant operation agent (Ex ib)
No
Suitable for safety functions
No
Explosion safety category for gas
None
Certified for UL hazardous location class I
No
Explosion safety category for dust
None
Certified for UL hazardous location class III
No
Certified for UL hazardous location class II
No
Certified for UL hazardous location group A (acetylene)
No
Certified for UL hazardous location division 1
No
Certified for UL hazardous location division 2
No
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group C (ethylene)
No
Certified for UL hazardous location group D (propane)
No
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group F (carbonaceous dusts)
No
Certified for UL hazardous location group G (non-conductive dusts)
No
Width
60mm
Height
100mm
Depth
100mm
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
Yes
Supporting protocol for PROFINET IO
No
Supporting protocol for Data-Highway
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for DNP3
No
Supporting protocol for IEC 61850 Ethernet
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
Yes
Supporting protocol for SafetyBUS p
No
Radio standard Wi-Fi 802.11
No
Supporting protocol for IEC 60870
No
Supporting protocol for SERCOS
No
Radio standard Bluetooth
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
XC-CPU101-FC128K-8DI-6DO

Details
- Programmable logic controllers PLC
- PLC CPU-module
- 1 KOM
- EATON
Technical specifications
Voltage type of supply voltage
DC
Supply voltage AC 60 Hz
0 .. 0V
Number of relay outputs
0
Supply voltage DC
20.4 .. 28.8V
Max. number of time switches
1000
Number of HW-interfaces industrial Ethernet
0
Processing time (1K, binary operation)
0.5ms
Number of interfaces PROFINET
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
1
Number of analogue outputs
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Number of analogue inputs
0
Number of HW-interfaces other
1
Number of digital inputs
8
Number of HW-interfaces RS-485
0
Supporting protocol for TCP/IP
Number of digital outputs
6
Supporting protocol for INTERBUS
Supply voltage AC 50 Hz
0 .. 0V
Supporting protocol for KNX
Supporting protocol for PROFIBUS
Supporting protocol for CAN
With optical interface
Number of HW-interfaces Wireless
0
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for EtherCAT
Model
Modular
Radio standard GPRS
Radio standard GSM
Radio standard UMTS
Long-Term Evolution (LTE)
System accessory
Redundancy
With display
Type of memory
RAM
IO link master
Memory size
128kByte
Additional program memory possible
Wall mounting/direct mounting
Rail mounting possible
Front built-in possible
Rack-assembly possible
SIL according to IEC 61508
None
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
Appendant operation agent (Ex ib)
Suitable for safety functions
Explosion safety category for gas
None
Certified for UL hazardous location class I
Explosion safety category for dust
None
Certified for UL hazardous location class III
Certified for UL hazardous location class II
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location division 1
Certified for UL hazardous location division 2
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group F (carbonaceous dusts)
Certified for UL hazardous location group G (non-conductive dusts)
Width
60mm
Height
100mm
Depth
100mm
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for PROFINET IO
Supporting protocol for Data-Highway
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET CBA
Supporting protocol for INTERBUS-Safety
Supporting protocol for DeviceNet Safety
Supporting protocol for DNP3
Supporting protocol for IEC 61850 Ethernet
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Radio standard Wi-Fi 802.11
Supporting protocol for IEC 60870
Supporting protocol for SERCOS
Radio standard Bluetooth
From same serie
Related products
We use cookies to enhance your experience.