Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as main switch
No
Version as maintenance-/service switch
No
Number of switches
1
Version as safety switch
No
Rated permanent current at AC-21, 400 V
32A
Rated permanent current Iu
32A
Rated operating voltage
690 - 690V
Rated permanent current at AC-23, 400 V
32A
Version as reversing switch
No
Rated operation power at AC-23, 400 V
15kW
Rated short-time withstand current lcw
0.65kA
Version as emergency stop installation
No
Rated operation power at AC-3, 400 V
11kW
Motor drive optional
No
Number of poles
6
Motor drive integrated
No
Suitable for front mounting 4-hole
No
Conditioned rated short-circuit current Iq
1kA
Number of auxiliary contacts as normally open contact
1
Voltage release optional
No
Number of auxiliary contacts as change-over contact
0
Suitable for front mounting centre
No
Switching power at 400 V
15kW
Suitable for floor mounting
Yes
Device construction
Complete device in housing
Suitable for intermediate mounting
No
Number of auxiliary contacts as normally closed contact
1
Colour control element
Black
Interlockable
No
Type of electrical connection of main circuit
Screw connection
Type of control element
Short thumb-grip
With pre-assembled cabling
No
Suitable for distribution board installation
No
Height
147mm
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Width
200mm
Depth
250mm
From same serie
T3-4-15682/SE2

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Max. rated operation voltage Ue AC
690V
Version as main switch
Version as maintenance-/service switch
Number of switches
1
Version as safety switch
Rated permanent current at AC-21, 400 V
32A
Rated permanent current Iu
32A
Rated operating voltage
690 .. 690V
Rated permanent current at AC-23, 400 V
32A
Version as reversing switch
Rated operation power at AC-23, 400 V
15kW
Rated short-time withstand current lcw
0.65kA
Version as emergency stop installation
Rated operation power at AC-3, 400 V
11kW
Motor drive optional
Number of poles
6
Motor drive integrated
Suitable for front mounting 4-hole
Conditioned rated short-circuit current Iq
1kA
Number of auxiliary contacts as normally open contact
1
Voltage release optional
Number of auxiliary contacts as change-over contact
0
Suitable for front mounting centre
Switching power at 400 V
15kW
Suitable for floor mounting
Device construction
Complete device in housing
Suitable for intermediate mounting
Number of auxiliary contacts as normally closed contact
1
Colour control element
Black
Interlockable
Type of electrical connection of main circuit
Screw connection
Type of control element
Short thumb-grip
With pre-assembled cabling
Suitable for distribution board installation
Height
147mm
Degree of protection (NEMA)
12
Degree of protection (IP), front side
IP65
Width
200mm
Depth
250mm
From same serie