

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP54
Width
128mm
Depth
190mm
Height
327mm
Degree of protection (NEMA)
12
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for LON
Yes
Supporting protocol for DeviceNet Safety
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for PROFIsafe
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for ASI
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
Supporting protocol for Data-Highway
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for other bus systems
Yes
Supporting protocol for KNX
No
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
0
Number of interfaces PROFINET
0
Number of HW-interfaces other
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Modbus
Yes
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
1
Number of digital inputs
6
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
With optical interface
No
With PC connection
Yes
4-quadrant operation possible
Yes
Integrated breaking resistance
Yes
Nominal output current I2N
3.3A
Max. output at linear load at rated output voltage
0.75kW
Application in domestic- and commercial area permitted
Yes
Max. output voltage
500V
Max. output frequency
320Hz
Mains voltage
323 - 550V
Application in industrial area permitted
Yes
Type of converter
U converter
Number of analogue outputs
1
Max. output at quadratic load at rated output voltage
1.1kW
Relative symmetric net voltage tolerance
10%
Number of phases output
3
Number of phases input
3
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Supporting protocol for BACnet
No
With control element
Yes
Number of analogue inputs
2
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SVX001A2-4A1B2

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP54
Width
128mm
Depth
190mm
Height
327mm
Degree of protection (NEMA)
12
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for LON
Supporting protocol for DeviceNet Safety
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for EtherNet/IP
Supporting protocol for PROFIsafe
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for other bus systems
Supporting protocol for KNX
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
0
Number of interfaces PROFINET
0
Number of HW-interfaces other
0
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for Foundation Fieldbus
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Modbus
Supporting protocol for SafetyBUS p
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
1
Number of digital inputs
6
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
With optical interface
With PC connection
4-quadrant operation possible
Integrated breaking resistance
Nominal output current I2N
3.3A
Max. output at linear load at rated output voltage
0.75kW
Application in domestic- and commercial area permitted
Max. output voltage
500V
Max. output frequency
320Hz
Mains voltage
323 .. 550V
Application in industrial area permitted
Type of converter
U converter
Number of analogue outputs
1
Max. output at quadratic load at rated output voltage
1.1kW
Relative symmetric net voltage tolerance
10%
Number of phases output
3
Number of phases input
3
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Supporting protocol for BACnet
With control element
Number of analogue inputs
2
From same serie
We use cookies to enhance your experience.