Technical specifications
Mains frequency
50/60 Hz
Max. output voltage
500V
Mains voltage
380 - 500V
Max. output at quadratic load at rated output voltage
630kW
Max. output at linear load at rated output voltage
560kW
Number of phases output
3
Application in domestic- and commercial area permitted
Yes
Number of phases input
3
Max. output frequency
320Hz
Number of analogue inputs
2
Nominal output current I2N
1150A
Application in industrial area permitted
Yes
Relative symmetric net voltage tolerance
10%
Number of digital inputs
6
Supporting protocol for SUCONET
No
With control element
Yes
Supporting protocol for Modbus
No
Number of digital outputs
1
Supporting protocol for Data-Highway
Yes
Supporting protocol for SERCOS
No
Supporting protocol for CAN
Yes
Supporting protocol for PROFINET IO
No
Supporting protocol for KNX
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for EtherNet/IP
No
Supporting protocol for ASI
No
Supporting protocol for DeviceNet Safety
No
Relative symmetric net frequency tolerance
10%
Supporting protocol for other bus systems
Yes
Supporting protocol for LON
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFINET CBA
No
Number of HW-interfaces RS-232
0
Number of HW-interfaces USB
0
Supporting protocol for SafetyBUS p
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Number of interfaces PROFINET
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces other
1
Supporting protocol for BACnet
No
Supporting protocol for INTERBUS
No
Supporting protocol for TCP/IP
Yes
Number of HW-interfaces RS-422
0
Supporting protocol for PROFIBUS
Yes
Number of analogue outputs
1
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
No
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (NEMA)
Other
Width
708mm
Degree of protection (IP)
IP00
Height
566mm
Depth
1055mm
Related products
From same serie
SPX800A0-4A2N1

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains frequency
50/60 Hz
Max. output voltage
500V
Mains voltage
380 .. 500V
Max. output at quadratic load at rated output voltage
630kW
Max. output at linear load at rated output voltage
560kW
Number of phases output
3
Application in domestic- and commercial area permitted
Number of phases input
3
Max. output frequency
320Hz
Number of analogue inputs
2
Nominal output current I2N
1150A
Application in industrial area permitted
Relative symmetric net voltage tolerance
10%
Number of digital inputs
6
Supporting protocol for SUCONET
With control element
Supporting protocol for Modbus
Number of digital outputs
1
Supporting protocol for Data-Highway
Supporting protocol for SERCOS
Supporting protocol for CAN
Supporting protocol for PROFINET IO
Supporting protocol for KNX
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet
Supporting protocol for EtherNet/IP
Supporting protocol for ASI
Supporting protocol for DeviceNet Safety
Relative symmetric net frequency tolerance
10%
Supporting protocol for other bus systems
Supporting protocol for LON
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET CBA
Number of HW-interfaces RS-232
0
Number of HW-interfaces USB
0
Supporting protocol for SafetyBUS p
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Number of interfaces PROFINET
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces other
1
Supporting protocol for BACnet
Supporting protocol for INTERBUS
Supporting protocol for TCP/IP
Number of HW-interfaces RS-422
0
Supporting protocol for PROFIBUS
Number of analogue outputs
1
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (NEMA)
Other
Width
708mm
Degree of protection (IP)
IP00
Height
566mm
Depth
1055mm