Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of digital inputs
6
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Number of analogue inputs
2
Nominal output current I2N
208A
Max. output voltage
690V
Max. output at linear load at rated output voltage
160kW
Max. output at quadratic load at rated output voltage
200kW
Number of phases output
3
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Relative symmetric net frequency tolerance
10%
Mains voltage
525 - 690V
Number of analogue outputs
1
Mains frequency
50/60 Hz
With control element
No
Application in industrial area permitted
No
Supporting protocol for CAN
No
Supporting protocol for KNX
No
Supporting protocol for ASI
No
Supporting protocol for PROFIBUS
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for Data-Highway
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for BACnet
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SafetyBUS p
No
With optical interface
No
Supporting protocol for PROFIsafe
No
Application in domestic- and commercial area permitted
No
Degree of protection (IP)
IP21
4-quadrant operation possible
No
Max. output frequency
320Hz
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS
No
Depth
1150mm
Degree of protection (NEMA)
Other
Height
362mm
Supporting protocol for Modbus
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Type of converter
Other
Supporting protocol for other bus systems
No
Supporting protocol for INTERBUS-Safety
No
Width
480mm
With PC connection
No
Integrated breaking resistance
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
SPX175A1-5A4N1
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of digital inputs
6
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Number of analogue inputs
2
Nominal output current I2N
208A
Max. output voltage
690V
Max. output at linear load at rated output voltage
160kW
Max. output at quadratic load at rated output voltage
200kW
Number of phases output
3
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Relative symmetric net frequency tolerance
10%
Mains voltage
525 .. 690V
Number of analogue outputs
1
Mains frequency
50/60 Hz
With control element
Application in industrial area permitted
Supporting protocol for CAN
Supporting protocol for KNX
Supporting protocol for ASI
Supporting protocol for PROFIBUS
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for Data-Highway
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for BACnet
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
With optical interface
Supporting protocol for PROFIsafe
Application in domestic- and commercial area permitted
Degree of protection (IP)
IP21
4-quadrant operation possible
Max. output frequency
320Hz
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS
Depth
1150mm
Degree of protection (NEMA)
Other
Height
362mm
Supporting protocol for Modbus
Supporting protocol for TCP/IP
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Type of converter
Other
Supporting protocol for other bus systems
Supporting protocol for INTERBUS-Safety
Width
480mm
With PC connection
Integrated breaking resistance
From same serie
Related products
We use cookies to enhance your experience.