Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of digital inputs
6
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Nominal output current I2N
170A
Number of analogue inputs
2
Max. output voltage
690V
Max. output at linear load at rated output voltage
132kW
Max. output at quadratic load at rated output voltage
160kW
Number of phases output
3
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Mains voltage
525 - 690V
Max. output frequency
320Hz
Application in industrial area permitted
No
Number of analogue outputs
1
Supporting protocol for TCP/IP
No
Application in domestic- and commercial area permitted
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
With control element
No
Supporting protocol for KNX
No
Supporting protocol for Data-Highway
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for CAN
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFIBUS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SUCONET
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for BACnet
No
With optical interface
No
Integrated breaking resistance
No
Supporting protocol for other bus systems
No
With PC connection
No
4-quadrant operation possible
No
Degree of protection (NEMA)
Other
Width
480mm
Type of converter
Other
Supporting protocol for PROFIsafe
No
Height
362mm
Depth
1150mm
Degree of protection (IP)
IP21
Supporting protocol for SafetyBUS p
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
SPX150A1-5A4N1

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of digital inputs
6
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Nominal output current I2N
170A
Number of analogue inputs
2
Max. output voltage
690V
Max. output at linear load at rated output voltage
132kW
Max. output at quadratic load at rated output voltage
160kW
Number of phases output
3
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Mains voltage
525 .. 690V
Max. output frequency
320Hz
Application in industrial area permitted
Number of analogue outputs
1
Supporting protocol for TCP/IP
Application in domestic- and commercial area permitted
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for DeviceNet
With control element
Supporting protocol for KNX
Supporting protocol for Data-Highway
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for CAN
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFIBUS
Supporting protocol for Foundation Fieldbus
Supporting protocol for SUCONET
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for BACnet
With optical interface
Integrated breaking resistance
Supporting protocol for other bus systems
With PC connection
4-quadrant operation possible
Degree of protection (NEMA)
Other
Width
480mm
Type of converter
Other
Supporting protocol for PROFIsafe
Height
362mm
Depth
1150mm
Degree of protection (IP)
IP21
Supporting protocol for SafetyBUS p
From same serie
Related products
We use cookies to enhance your experience.