Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Number of analogue inputs
2
Number of digital inputs
6
Nominal output current I2N
170A
Max. output at linear load at rated output voltage
75kW
Max. output voltage
500V
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
90kW
Relative symmetric net frequency tolerance
10%
Number of phases output
3
Number of phases input
3
Mains frequency
50/60 Hz
Max. output frequency
320Hz
Mains voltage
380 - 500V
Supporting protocol for ASI
No
Application in industrial area permitted
No
Supporting protocol for CAN
No
With control element
No
Number of analogue outputs
1
Supporting protocol for PROFIBUS
No
Supporting protocol for TCP/IP
No
Supporting protocol for KNX
No
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Application in domestic- and commercial area permitted
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for Data-Highway
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SafetyBUS p
No
Integrated breaking resistance
No
Type of converter
Other
Supporting protocol for PROFINET IO
No
With optical interface
No
4-quadrant operation possible
No
With PC connection
No
Degree of protection (NEMA)
Other
Supporting protocol for PROFIsafe
No
Supporting protocol for BACnet
No
Supporting protocol for DeviceNet Safety
No
Height
344mm
Supporting protocol for other bus systems
No
Supporting protocol for INTERBUS-Safety
No
Degree of protection (IP)
IP54
Width
291mm
Depth
758mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
SPX100A2-4A1N1
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Number of analogue inputs
2
Number of digital inputs
6
Nominal output current I2N
170A
Max. output at linear load at rated output voltage
75kW
Max. output voltage
500V
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
90kW
Relative symmetric net frequency tolerance
10%
Number of phases output
3
Number of phases input
3
Mains frequency
50/60 Hz
Max. output frequency
320Hz
Mains voltage
380 .. 500V
Supporting protocol for ASI
Application in industrial area permitted
Supporting protocol for CAN
With control element
Number of analogue outputs
1
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Supporting protocol for KNX
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Application in domestic- and commercial area permitted
Supporting protocol for PROFINET CBA
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for Data-Highway
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SafetyBUS p
Integrated breaking resistance
Type of converter
Other
Supporting protocol for PROFINET IO
With optical interface
4-quadrant operation possible
With PC connection
Degree of protection (NEMA)
Other
Supporting protocol for PROFIsafe
Supporting protocol for BACnet
Supporting protocol for DeviceNet Safety
Height
344mm
Supporting protocol for other bus systems
Supporting protocol for INTERBUS-Safety
Degree of protection (IP)
IP54
Width
291mm
Depth
758mm
From same serie
Related products
We use cookies to enhance your experience.