Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Number of analogue inputs
2
Number of digital inputs
6
Nominal output current I2N
100A
Max. output at linear load at rated output voltage
75kW
Max. output voltage
690V
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
90kW
Number of phases output
3
Relative symmetric net frequency tolerance
10%
Number of phases input
3
Mains voltage
525 - 690V
Mains frequency
50/60 Hz
Max. output frequency
320Hz
Application in industrial area permitted
No
Supporting protocol for TCP/IP
No
Number of analogue outputs
1
Supporting protocol for INTERBUS
No
Supporting protocol for PROFIBUS
No
Application in domestic- and commercial area permitted
No
With control element
No
Supporting protocol for CAN
No
Supporting protocol for KNX
No
Supporting protocol for Modbus
No
Supporting protocol for ASI
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for SERCOS
No
Supporting protocol for LON
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET IO
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFIsafe
No
With optical interface
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Supporting protocol for BACnet
No
Degree of protection (IP)
IP54
4-quadrant operation possible
No
Integrated breaking resistance
No
Width
291mm
Height
344mm
Degree of protection (NEMA)
Other
With PC connection
No
Type of converter
Other
Depth
758mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
SPX075A2-5A4N1

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
1
Number of HW-interfaces parallel
0
Number of HW-interfaces other
0
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Number of analogue inputs
2
Number of digital inputs
6
Nominal output current I2N
100A
Max. output at linear load at rated output voltage
75kW
Max. output voltage
690V
Relative symmetric net voltage tolerance
10%
Max. output at quadratic load at rated output voltage
90kW
Number of phases output
3
Relative symmetric net frequency tolerance
10%
Number of phases input
3
Mains voltage
525 .. 690V
Mains frequency
50/60 Hz
Max. output frequency
320Hz
Application in industrial area permitted
Supporting protocol for TCP/IP
Number of analogue outputs
1
Supporting protocol for INTERBUS
Supporting protocol for PROFIBUS
Application in domestic- and commercial area permitted
With control element
Supporting protocol for CAN
Supporting protocol for KNX
Supporting protocol for Modbus
Supporting protocol for ASI
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for LON
Supporting protocol for INTERBUS-Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFIsafe
With optical interface
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Supporting protocol for BACnet
Degree of protection (IP)
IP54
4-quadrant operation possible
Integrated breaking resistance
Width
291mm
Height
344mm
Degree of protection (NEMA)
Other
With PC connection
Type of converter
Other
Depth
758mm
From same serie
Related products
We use cookies to enhance your experience.