Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP21
Height
558mm
Width
195mm
Depth
237mm
Degree of protection (NEMA)
1
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for ASI
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for CAN
Yes
Supporting protocol for Data-Highway
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces RS-422
0
Supporting protocol for KNX
No
Number of HW-interfaces RS-485
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces other
0
Supporting protocol for LON
Yes
Supporting protocol for PROFIsafe
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for Modbus
Yes
Number of HW-interfaces RS-232
1
Number of digital inputs
6
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
With optical interface
No
Number of analogue inputs
2
Nominal output current I2N
34A
4-quadrant operation possible
Yes
Number of analogue outputs
1
Integrated breaking resistance
Yes
With PC connection
Yes
Application in domestic- and commercial area permitted
Yes
Max. output frequency
320Hz
Max. output at linear load at rated output voltage
22kW
Max. output voltage
690V
Mains voltage
447 - 759V
Application in industrial area permitted
Yes
Type of converter
U converter
Max. output at quadratic load at rated output voltage
30kW
Relative symmetric net voltage tolerance
10%
Number of phases output
3
Relative symmetric net frequency tolerance
10%
Number of phases input
3
Mains frequency
50/60 Hz
Supporting protocol for BACnet
No
With control element
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
SPX025A1-5A4B1
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP21
Height
558mm
Width
195mm
Depth
237mm
Degree of protection (NEMA)
1
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SUCONET
Supporting protocol for DeviceNet Safety
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet
Supporting protocol for PROFINET CBA
Supporting protocol for SafetyBUS p
Supporting protocol for ASI
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for other bus systems
Number of HW-interfaces RS-422
0
Supporting protocol for KNX
Number of HW-interfaces RS-485
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
0
Number of HW-interfaces other
0
Supporting protocol for LON
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Supporting protocol for PROFIBUS
Supporting protocol for Modbus
Number of HW-interfaces RS-232
1
Number of digital inputs
6
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
With optical interface
Number of analogue inputs
2
Nominal output current I2N
34A
4-quadrant operation possible
Number of analogue outputs
1
Integrated breaking resistance
With PC connection
Application in domestic- and commercial area permitted
Max. output frequency
320Hz
Max. output at linear load at rated output voltage
22kW
Max. output voltage
690V
Mains voltage
447 .. 759V
Application in industrial area permitted
Type of converter
U converter
Max. output at quadratic load at rated output voltage
30kW
Relative symmetric net voltage tolerance
10%
Number of phases output
3
Relative symmetric net frequency tolerance
10%
Number of phases input
3
Mains frequency
50/60 Hz
Supporting protocol for BACnet