

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
Number of poles
4
System configuration other
Yes
System configuration TN-C-S
No
System configuration TN
Yes
System configuration TT
Yes
System configuration TN-S
Yes
System configuration IT
Yes
System configuration DC
No
Voltage protection level L-PE
1.5kV
Lightning impulse current (10/350 µs)
12.5kA
System configuration TN-C
No
Nominal voltage DC
0V
Voltage protection level L-N
1.5kV
Nominal voltage AC
240V
Voltage protection level
1.5kV
Specific energy (W/R)
625kJ/Ohm
Voltage protection level (DC+ - DC-)
0kV
Max. PV-voltage
0V
Max. continuous voltage AC
260V
Max. continuous voltage DC
0V
Voltage protection level (DC+/DC- - PE)
0kV
Voltage protection level N-PE
1.4kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Construction size
4 modular spacing
Max. overcurrent protection device, series connection (fuse)
0A
Mounting method
DIN rail (top hat rail) 35 mm
Follow current extinguishing capability
0kA
Energy-coordinated protection effect with regard to the terminal equipment
No
Signalling at the device
Optic
Max. conductor cross section flexible (fine-strand)
35mm²
Voltage switching spark gap technology
Yes
Max. conductor cross section solid (solid, stranded)
25mm²
Test class
Type 1 + 2
Remote signalling
No
Integrated backup fuse
No
Overcurrent protected voltage tapping
No
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPBT12-280-3+NPE50

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
Number of poles
4
System configuration other
System configuration TN-C-S
System configuration TN
System configuration TT
System configuration TN-S
System configuration IT
System configuration DC
Voltage protection level L-PE
1.5kV
Lightning impulse current (10/350 µs)
12.5kA
System configuration TN-C
Nominal voltage DC
0V
Voltage protection level L-N
1.5kV
Nominal voltage AC
240V
Voltage protection level
1.5kV
Specific energy (W/R)
625kJ/Ohm
Voltage protection level (DC+ - DC-)
0kV
Max. PV-voltage
0V
Max. continuous voltage AC
260V
Max. continuous voltage DC
0V
Voltage protection level (DC+/DC- - PE)
0kV
Voltage protection level N-PE
1.4kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Construction size
4 modular spacing
Max. overcurrent protection device, series connection (fuse)
0A
Mounting method
DIN rail (top hat rail) 35 mm
Follow current extinguishing capability
0kA
Energy-coordinated protection effect with regard to the terminal equipment
Signalling at the device
Optic
Max. conductor cross section flexible (fine-strand)
35mm²
Voltage switching spark gap technology
Max. conductor cross section solid (solid, stranded)
25mm²
Test class
Type 1 + 2
Remote signalling
Integrated backup fuse
Overcurrent protected voltage tapping
Degree of protection (IP)
IP20
From same serie
We use cookies to enhance your experience.