Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration IT
Yes
System configuration TN
Yes
System configuration TT
Yes
Number of poles
4
System configuration DC
No
Max. continuous voltage DC
0V
System configuration TN-C-S
No
Nominal voltage DC
0V
Voltage protection level
1.5kV
Voltage protection level N-PE
1.4kV
System configuration TN-S
Yes
Voltage protection level L-N
1.5kV
Max. continuous voltage AC
260V
Max. PV-voltage
0V
Specific energy (W/R)
625kJ/Ohm
Voltage protection level L-PE
1.5kV
Voltage protection level (DC+ - DC-)
0kV
Max. overcurrent protection device, series connection (fuse)
0A
System configuration TN-C
No
System configuration other
Yes
Follow current extinguishing capability
0kA
Lightning impulse current (10/350 µs)
12.5kA
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level (DC+/DC- - PE)
0kV
Nominal voltage AC
240V
Mounting method
DIN rail (top hat rail) 35 mm
Max. conductor cross section flexible (fine-strand)
35mm²
Max. conductor cross section solid (solid, stranded)
25mm²
Construction size
4 modular spacing
Remote signalling
No
Degree of protection (IP)
IP20
Voltage switching spark gap technology
Yes
Test class
Type 1 + 2
Overcurrent protected voltage tapping
No
Energy-coordinated protection effect with regard to the terminal equipment
No
Signalling at the device
Optic
Integrated backup fuse
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPBT12-280-3+NPE50
Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration IT
System configuration TN
System configuration TT
Number of poles
4
System configuration DC
Max. continuous voltage DC
0V
System configuration TN-C-S
Nominal voltage DC
0V
Voltage protection level
1.5kV
Voltage protection level N-PE
1.4kV
System configuration TN-S
Voltage protection level L-N
1.5kV
Max. continuous voltage AC
260V
Max. PV-voltage
0V
Specific energy (W/R)
625kJ/Ohm
Voltage protection level L-PE
1.5kV
Voltage protection level (DC+ - DC-)
0kV
Max. overcurrent protection device, series connection (fuse)
0A
System configuration TN-C
System configuration other
Follow current extinguishing capability
0kA
Lightning impulse current (10/350 µs)
12.5kA
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level (DC+/DC- - PE)
0kV
Nominal voltage AC
240V
Mounting method
DIN rail (top hat rail) 35 mm
Max. conductor cross section flexible (fine-strand)
35mm²
Max. conductor cross section solid (solid, stranded)
25mm²
Construction size
4 modular spacing
Remote signalling
Degree of protection (IP)
IP20
Voltage switching spark gap technology
Test class
Type 1 + 2
Overcurrent protected voltage tapping
Energy-coordinated protection effect with regard to the terminal equipment
Signalling at the device
Optic
Integrated backup fuse