Details
- Programmable logic controllers PLC
- Logic module
- 1 KOM
- EATON
Technical specifications
Switching current
0.5A
Power consumption
2W
Voltage type of supply voltage
DC
Supply voltage AC 60 Hz
0 - 0V
Supply voltage DC
20.4 - 28.8V
Supply voltage AC 50 Hz
0 - 0V
Number of analogue outputs
0
Number of analogue inputs
4
Number of digital outputs
4
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of digital inputs
4
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
With relay output
No
Supporting protocol for PROFIBUS
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
With optical interface
No
Number of HW-interfaces Wireless
0
Supporting protocol for EtherCAT
No
Supporting protocol for ASI
No
Supporting protocol for Modbus
Yes
Number of HW-interfaces RS-485
0
Supporting protocol for KNX
No
Number of HW-interfaces other
0
Redundancy
No
IO link master
No
With display
No
Degree of protection (IP)
IP20
Basic device
No
Expandable
Yes
Expansion device
No
With time switch clock
Yes
Rail mounting possible
Yes
Wall mounting/direct mounting
No
Rack-assembly possible
No
Front built-in possible
Yes
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
No
SIL according to IEC 61508
None
Suitable for safety functions
No
Explosion safety category for dust
None
Certified for UL hazardous location class I
Yes
Explosion safety category for gas
None
Certified for UL hazardous location class II
No
Appendant operation agent (Ex ib)
No
Certified for UL hazardous location class III
No
Certified for UL hazardous location division 2
Yes
Certified for UL hazardous location division 1
No
Certified for UL hazardous location group C (ethylene)
Yes
Certified for UL hazardous location group B (hydrogen)
No
Certified for UL hazardous location group A (acetylene)
Yes
Certified for UL hazardous location group E (metal dusts)
No
Certified for UL hazardous location group D (propane)
Yes
Certified for UL hazardous location group F (carbonaceous dusts)
No
Width
72mm
Height
90mm
Certified for UL hazardous location group G (non-conductive dusts)
No
Depth
58mm
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Radio standard GPRS
No
Radio standard Bluetooth
No
Supporting protocol for SafetyBUS p
No
Radio standard Wi-Fi 802.11
No
Supporting protocol for other bus systems
No
Radio standard GSM
No
Radio standard UMTS
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
EASY-E4-DC-12TCX1P

Details
- Programmable logic controllers PLC
- Logic module
- 1 KOM
- EATON
Technical specifications
Switching current
0.5A
Power consumption
2W
Voltage type of supply voltage
DC
Supply voltage AC 60 Hz
0 .. 0V
Supply voltage DC
20.4 .. 28.8V
Supply voltage AC 50 Hz
0 .. 0V
Number of analogue outputs
0
Number of analogue inputs
4
Number of digital outputs
4
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Number of digital inputs
4
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
With relay output
Supporting protocol for PROFIBUS
Supporting protocol for TCP/IP
Supporting protocol for CAN
Supporting protocol for INTERBUS
With optical interface
Number of HW-interfaces Wireless
0
Supporting protocol for EtherCAT
Supporting protocol for ASI
Supporting protocol for Modbus
Number of HW-interfaces RS-485
0
Supporting protocol for KNX
Number of HW-interfaces other
0
Redundancy
IO link master
With display
Degree of protection (IP)
IP20
Basic device
Expandable
Expansion device
With time switch clock
Rail mounting possible
Wall mounting/direct mounting
Rack-assembly possible
Front built-in possible
Performance level according to EN ISO 13849-1
None
Appendant operation agent (Ex ia)
SIL according to IEC 61508
None
Suitable for safety functions
Explosion safety category for dust
None
Certified for UL hazardous location class I
Explosion safety category for gas
None
Certified for UL hazardous location class II
Appendant operation agent (Ex ib)
Certified for UL hazardous location class III
Certified for UL hazardous location division 2
Certified for UL hazardous location division 1
Certified for UL hazardous location group C (ethylene)
Certified for UL hazardous location group B (hydrogen)
Certified for UL hazardous location group A (acetylene)
Certified for UL hazardous location group E (metal dusts)
Certified for UL hazardous location group D (propane)
Certified for UL hazardous location group F (carbonaceous dusts)
Width
72mm
Height
90mm
Certified for UL hazardous location group G (non-conductive dusts)
Depth
58mm
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Radio standard GPRS
Radio standard Bluetooth
Supporting protocol for SafetyBUS p
Radio standard Wi-Fi 802.11
Supporting protocol for other bus systems
Radio standard GSM
Radio standard UMTS