Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 - 480V
Relative symmetric net voltage tolerance
10%
Mains frequency
50/60 Hz
Number of phases output
3
Supporting protocol for CAN
Yes
Number of phases input
3
With control element
Yes
Max. output at quadratic load at rated output voltage
2.2kW
Number of digital inputs
4
Number of analogue inputs
1
Supporting protocol for DeviceNet
No
Nominal output current I2N
4.3A
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for BACnet
Yes
Supporting protocol for DeviceNet Safety
No
Max. output frequency
400Hz
Supporting protocol for SUCONET
No
Supporting protocol for AS-Interface Safety at Work
No
Max. output at linear load at rated output voltage
1.5kW
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for Data-Highway
No
Number of HW-interfaces RS-232
0
Number of HW-interfaces parallel
0
Number of analogue outputs
1
Max. output voltage
500V
Application in domestic- and commercial area permitted
Yes
Supporting protocol for ASI
No
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for INTERBUS
No
Supporting protocol for SERCOS
No
Power consumption
75W
Application in industrial area permitted
Yes
Number of digital outputs
0
Supporting protocol for TCP/IP
Yes
Supporting protocol for PROFIBUS
Yes
Number of HW-interfaces RS-485
1
Supporting protocol for LON
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for Modbus
Yes
Supporting protocol for PROFIsafe
No
Supporting protocol for EtherNet/IP
Yes
Relative symmetric net frequency tolerance
10%
Number of HW-interfaces USB
0
Supporting protocol for other bus systems
Yes
Supporting protocol for PROFINET IO
No
With PC connection
Yes
Supporting protocol for KNX
No
Number of HW-interfaces other
1
With optical interface
No
Integrated breaking resistance
Yes
4-quadrant operation possible
Yes
Degree of protection (IP)
IP20
Type of converter
U converter
Width
72mm
Depth
180mm
Height
152mm
Degree of protection (NEMA)
Other
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
DM1-344D3NB-S20S-EM
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 .. 480V
Relative symmetric net voltage tolerance
10%
Mains frequency
50/60 Hz
Number of phases output
3
Supporting protocol for CAN
Number of phases input
3
With control element
Max. output at quadratic load at rated output voltage
2.2kW
Number of digital inputs
4
Number of analogue inputs
1
Supporting protocol for DeviceNet
Nominal output current I2N
4.3A
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Supporting protocol for BACnet
Supporting protocol for DeviceNet Safety
Max. output frequency
400Hz
Supporting protocol for SUCONET
Supporting protocol for AS-Interface Safety at Work
Max. output at linear load at rated output voltage
1.5kW
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for Data-Highway
Number of HW-interfaces RS-232
0
Number of HW-interfaces parallel
0
Number of analogue outputs
1
Max. output voltage
500V
Application in domestic- and commercial area permitted
Supporting protocol for ASI
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Supporting protocol for INTERBUS-Safety
Supporting protocol for INTERBUS
Supporting protocol for SERCOS
Power consumption
75W
Application in industrial area permitted
Number of digital outputs
0
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Number of HW-interfaces RS-485
1
Supporting protocol for LON
Supporting protocol for SafetyBUS p
Supporting protocol for Modbus
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Relative symmetric net frequency tolerance
10%
Number of HW-interfaces USB
0
Supporting protocol for other bus systems
Supporting protocol for PROFINET IO
With PC connection
Supporting protocol for KNX
Number of HW-interfaces other
1
With optical interface
Integrated breaking resistance
4-quadrant operation possible
Degree of protection (IP)
IP20
Type of converter
U converter
Width
72mm
Depth
180mm
Height
152mm
Degree of protection (NEMA)
Other
From same serie
We use cookies to enhance your experience.