Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output frequency
400Hz
Nominal output current I2N
38A
Number of phases output
3
Number of phases input
3
Max. output at quadratic load at rated output voltage
22kW
Mains voltage
380 - 480V
Power consumption
473.4W
Number of analogue outputs
1
Max. output at linear load at rated output voltage
18.5kW
With control element
Yes
Number of digital inputs
4
Supporting protocol for PROFIBUS
Yes
Application in domestic- and commercial area permitted
Yes
Number of digital outputs
0
Supporting protocol for KNX
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for CAN
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for Modbus
Yes
Relative symmetric net frequency tolerance
10%
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
1
Max. output voltage
500V
Mains frequency
50/60 Hz
Application in industrial area permitted
Yes
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for Foundation Fieldbus
No
Number of HW-interfaces other
1
With optical interface
No
Integrated breaking resistance
Yes
With PC connection
Yes
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for DeviceNet Safety
No
Width
184mm
Height
300mm
Depth
195mm
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for BACnet
Yes
Supporting protocol for other bus systems
Yes
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces industrial Ethernet
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
DM1-34038EB-S20S-EM
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output frequency
400Hz
Nominal output current I2N
38A
Number of phases output
3
Number of phases input
3
Max. output at quadratic load at rated output voltage
22kW
Mains voltage
380 .. 480V
Power consumption
473.4W
Number of analogue outputs
1
Max. output at linear load at rated output voltage
18.5kW
With control element
Number of digital inputs
4
Supporting protocol for PROFIBUS
Application in domestic- and commercial area permitted
Number of digital outputs
0
Supporting protocol for KNX
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for TCP/IP
Supporting protocol for Modbus
Relative symmetric net frequency tolerance
10%
Relative symmetric net voltage tolerance
10%
Number of analogue inputs
1
Max. output voltage
500V
Mains frequency
50/60 Hz
Application in industrial area permitted
Supporting protocol for PROFINET IO
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Number of HW-interfaces other
1
With optical interface
Integrated breaking resistance
With PC connection
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
Supporting protocol for DeviceNet Safety
Width
184mm
Height
300mm
Depth
195mm
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Supporting protocol for BACnet
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Number of HW-interfaces industrial Ethernet
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces parallel
0
Number of HW-interfaces serial TTY
0
From same serie