Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
200 - 240V
Nominal output current I2N
7.8A
Max. output voltage
240V
Power consumption
99W
Number of phases output
3
Max. output frequency
400Hz
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Number of digital outputs
0
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Supporting protocol for TCP/IP
Yes
Number of analogue outputs
1
Number of digital inputs
4
With control element
Yes
Supporting protocol for KNX
No
Application in industrial area permitted
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for CAN
Yes
Max. output at linear load at rated output voltage
1.5kW
Supporting protocol for SUCONET
No
Supporting protocol for Modbus
Yes
Application in domestic- and commercial area permitted
Yes
Supporting protocol for LON
No
Number of analogue inputs
1
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Max. output at quadratic load at rated output voltage
2.2kW
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Number of HW-interfaces other
1
With optical interface
No
Integrated breaking resistance
Yes
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
With PC connection
Yes
4-quadrant operation possible
Yes
Height
152mm
Depth
180mm
Width
72mm
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for INTERBUS-Safety
No
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for other bus systems
Yes
Supporting protocol for BACnet
Yes
Number of HW-interfaces parallel
0
Supporting protocol for DeviceNet Safety
No
Supporting protocol for EtherNet/IP
Yes
Number of interfaces PROFINET
0
Supporting protocol for AS-Interface Safety at Work
No
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces USB
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
DM1-327D8NB-S20S-EM
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
200 .. 240V
Nominal output current I2N
7.8A
Max. output voltage
240V
Power consumption
99W
Number of phases output
3
Max. output frequency
400Hz
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Number of digital outputs
0
Relative symmetric net voltage tolerance
10%
Number of phases input
3
Supporting protocol for TCP/IP
Number of analogue outputs
1
Number of digital inputs
4
With control element
Supporting protocol for KNX
Application in industrial area permitted
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for CAN
Max. output at linear load at rated output voltage
1.5kW
Supporting protocol for SUCONET
Supporting protocol for Modbus
Application in domestic- and commercial area permitted
Supporting protocol for LON
Number of analogue inputs
1
Supporting protocol for SERCOS
Supporting protocol for PROFINET IO
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Max. output at quadratic load at rated output voltage
2.2kW
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
Number of HW-interfaces other
1
With optical interface
Integrated breaking resistance
Type of converter
U converter
Degree of protection (IP)
IP20
Degree of protection (NEMA)
Other
With PC connection
4-quadrant operation possible
Height
152mm
Depth
180mm
Width
72mm
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for other bus systems
Supporting protocol for BACnet
Number of HW-interfaces parallel
0
Supporting protocol for DeviceNet Safety
Supporting protocol for EtherNet/IP
Number of interfaces PROFINET
0
Supporting protocol for AS-Interface Safety at Work
Number of HW-interfaces RS-485
1
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces USB
0
From same serie
We use cookies to enhance your experience.