Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output at quadratic load at rated output voltage
11kW
Mains voltage
200 - 240V
Power consumption
432.4W
Max. output voltage
240V
Number of phases output
3
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Number of phases input
3
Max. output at linear load at rated output voltage
7.5kW
Number of analogue outputs
1
Max. output frequency
400Hz
Relative symmetric net voltage tolerance
10%
With control element
Yes
Number of analogue inputs
1
Supporting protocol for TCP/IP
Yes
Application in industrial area permitted
Yes
Number of digital inputs
4
Application in domestic- and commercial area permitted
Yes
Supporting protocol for CAN
Yes
Supporting protocol for ASI
No
Number of digital outputs
0
Supporting protocol for PROFIBUS
Yes
Supporting protocol for KNX
No
Nominal output current I2N
32.2A
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
Yes
Number of HW-interfaces other
1
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
Yes
4-quadrant operation possible
Yes
Degree of protection (IP)
IP20
Type of converter
U converter
Degree of protection (NEMA)
Other
Height
300mm
Width
184mm
Depth
195mm
Supporting protocol for PROFINET CBA
No
Supporting protocol for SUCONET
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for DeviceNet
No
Supporting protocol for PROFINET IO
No
Supporting protocol for LON
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for BACnet
Yes
Supporting protocol for other bus systems
Yes
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-485
1
Supporting protocol for DeviceNet Safety
No
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
DM1-32032EB-S20S-EM
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output at quadratic load at rated output voltage
11kW
Mains voltage
200 .. 240V
Power consumption
432.4W
Max. output voltage
240V
Number of phases output
3
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Number of phases input
3
Max. output at linear load at rated output voltage
7.5kW
Number of analogue outputs
1
Max. output frequency
400Hz
Relative symmetric net voltage tolerance
10%
With control element
Number of analogue inputs
1
Supporting protocol for TCP/IP
Application in industrial area permitted
Number of digital inputs
4
Application in domestic- and commercial area permitted
Supporting protocol for CAN
Supporting protocol for ASI
Number of digital outputs
0
Supporting protocol for PROFIBUS
Supporting protocol for KNX
Nominal output current I2N
32.2A
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Number of HW-interfaces other
1
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Degree of protection (IP)
IP20
Type of converter
U converter
Degree of protection (NEMA)
Other
Height
300mm
Width
184mm
Depth
195mm
Supporting protocol for PROFINET CBA
Supporting protocol for SUCONET
Supporting protocol for EtherNet/IP
Supporting protocol for DeviceNet
Supporting protocol for PROFINET IO
Supporting protocol for LON
Supporting protocol for Foundation Fieldbus
Supporting protocol for Data-Highway
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SERCOS
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS-Safety
Supporting protocol for BACnet
Supporting protocol for other bus systems
Number of HW-interfaces RS-232
0
Number of interfaces PROFINET
0
Supporting protocol for SafetyBUS p
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-485
1
Supporting protocol for DeviceNet Safety
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-422
0
From same serie