Technical specifications
Max. output frequency
400Hz
Mains voltage
380 - 500V
Max. output at linear load at rated output voltage
75kW
Power consumption
1594W
Number of analogue outputs
2
Number of phases input
3
Max. output at quadratic load at rated output voltage
90kW
Nominal output current I2N
140A
Number of digital outputs
1
Max. output voltage
500V
Number of digital inputs
8
With control element
Yes
Application in industrial area permitted
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
Yes
Number of phases output
3
Supporting protocol for ASI
No
Relative symmetric net voltage tolerance
10%
Supporting protocol for TCP/IP
Yes
Supporting protocol for KNX
No
Relative symmetric net frequency tolerance
10%
Supporting protocol for CAN
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Number of analogue inputs
2
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for LON
No
Application in domestic- and commercial area permitted
Yes
Mains frequency
50/60 Hz
Number of HW-interfaces RS-485
1
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
Yes
Supporting protocol for PROFINET CBA
No
Number of HW-interfaces RS-422
0
Supporting protocol for EtherNet/IP
Yes
Number of interfaces PROFINET
0
Supporting protocol for PROFIsafe
No
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces USB
0
Supporting protocol for PROFIBUS
Yes
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for other bus systems
Yes
Supporting protocol for SERCOS
No
Number of HW-interfaces parallel
0
Number of HW-interfaces other
1
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-232
0
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
No
4-quadrant operation possible
No
Degree of protection (NEMA)
1
Degree of protection (IP)
IP21
Type of converter
U converter
Height
888.5mm
Width
288mm
Depth
340.7mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DG1-34140FN-C21C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output frequency
400Hz
Mains voltage
380 .. 500V
Max. output at linear load at rated output voltage
75kW
Power consumption
1594W
Number of analogue outputs
2
Number of phases input
3
Max. output at quadratic load at rated output voltage
90kW
Nominal output current I2N
140A
Number of digital outputs
1
Max. output voltage
500V
Number of digital inputs
8
With control element
Application in industrial area permitted
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Number of phases output
3
Supporting protocol for ASI
Relative symmetric net voltage tolerance
10%
Supporting protocol for TCP/IP
Supporting protocol for KNX
Relative symmetric net frequency tolerance
10%
Supporting protocol for CAN
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Number of analogue inputs
2
Supporting protocol for Foundation Fieldbus
Supporting protocol for Data-Highway
Supporting protocol for PROFINET IO
Supporting protocol for LON
Application in domestic- and commercial area permitted
Mains frequency
50/60 Hz
Number of HW-interfaces RS-485
1
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Supporting protocol for PROFINET CBA
Number of HW-interfaces RS-422
0
Supporting protocol for EtherNet/IP
Number of interfaces PROFINET
0
Supporting protocol for PROFIsafe
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces USB
0
Supporting protocol for PROFIBUS
Supporting protocol for INTERBUS-Safety
Supporting protocol for other bus systems
Supporting protocol for SERCOS
Number of HW-interfaces parallel
0
Number of HW-interfaces other
1
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-232
0
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Degree of protection (NEMA)
1
Degree of protection (IP)
IP21
Type of converter
U converter
Height
888.5mm
Width
288mm
Depth
340.7mm