Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains frequency
50/60 Hz
Number of phases input
3
Number of phases output
3
Max. output frequency
400Hz
Max. output at quadratic load at rated output voltage
55kW
Relative symmetric net voltage tolerance
10%
Max. output voltage
500V
With control element
Yes
Nominal output current I2N
87A
Supporting protocol for TCP/IP
Yes
Application in domestic- and commercial area permitted
Yes
Power consumption
1217W
Supporting protocol for PROFIBUS
Yes
Supporting protocol for KNX
No
Application in industrial area permitted
Yes
Number of digital outputs
1
Number of digital inputs
8
Number of analogue inputs
2
Relative symmetric net frequency tolerance
10%
Number of analogue outputs
2
Supporting protocol for INTERBUS
No
Mains voltage
380 - 500V
Supporting protocol for CAN
Yes
Max. output at linear load at rated output voltage
45kW
Supporting protocol for ASI
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
Yes
Number of HW-interfaces other
1
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
No
4-quadrant operation possible
No
Type of converter
U converter
Degree of protection (IP)
IP21
Height
630mm
Degree of protection (NEMA)
1
Depth
294mm
Width
237.7mm
Supporting protocol for PROFINET CBA
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for PROFINET IO
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet Safety
No
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for other bus systems
Yes
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for LON
No
Supporting protocol for INTERBUS-Safety
No
Number of HW-interfaces USB
0
Number of HW-interfaces RS-422
0
Supporting protocol for BACnet
Yes
Number of HW-interfaces RS-232
0
Supporting protocol for PROFIsafe
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DG1-34087FN-C21C

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains frequency
50/60 Hz
Number of phases input
3
Number of phases output
3
Max. output frequency
400Hz
Max. output at quadratic load at rated output voltage
55kW
Relative symmetric net voltage tolerance
10%
Max. output voltage
500V
With control element
Nominal output current I2N
87A
Supporting protocol for TCP/IP
Application in domestic- and commercial area permitted
Power consumption
1217W
Supporting protocol for PROFIBUS
Supporting protocol for KNX
Application in industrial area permitted
Number of digital outputs
1
Number of digital inputs
8
Number of analogue inputs
2
Relative symmetric net frequency tolerance
10%
Number of analogue outputs
2
Supporting protocol for INTERBUS
Mains voltage
380 .. 500V
Supporting protocol for CAN
Max. output at linear load at rated output voltage
45kW
Supporting protocol for ASI
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Number of HW-interfaces other
1
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP21
Height
630mm
Degree of protection (NEMA)
1
Depth
294mm
Width
237.7mm
Supporting protocol for PROFINET CBA
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for PROFINET IO
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SERCOS
Supporting protocol for DeviceNet Safety
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for other bus systems
Supporting protocol for EtherNet/IP
Supporting protocol for LON
Supporting protocol for INTERBUS-Safety
Number of HW-interfaces USB
0
Number of HW-interfaces RS-422
0
Supporting protocol for BACnet
Number of HW-interfaces RS-232
0
Supporting protocol for PROFIsafe
Supporting protocol for Foundation Fieldbus
Supporting protocol for SafetyBUS p
Number of HW-interfaces serial TTY
0
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
From same serie
Related products
We use cookies to enhance your experience.