Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output voltage
500V
Power consumption
914W
Mains voltage
380 - 500V
Mains frequency
50/60 Hz
Relative symmetric net frequency tolerance
10%
Relative symmetric net voltage tolerance
10%
Max. output at linear load at rated output voltage
37kW
Application in industrial area permitted
Yes
Number of phases input
3
Number of digital inputs
8
Number of analogue inputs
2
Supporting protocol for ASI
No
Supporting protocol for KNX
No
Supporting protocol for CAN
Yes
Max. output frequency
400Hz
Max. output at quadratic load at rated output voltage
45kW
Application in domestic- and commercial area permitted
Yes
Supporting protocol for PROFINET IO
Yes
Number of analogue outputs
2
Supporting protocol for SUCONET
No
Nominal output current I2N
72A
Supporting protocol for Foundation Fieldbus
No
Number of digital outputs
1
Supporting protocol for Modbus
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for TCP/IP
Yes
Supporting protocol for LON
No
With control element
Yes
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Number of phases output
3
Number of HW-interfaces other
1
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
No
4-quadrant operation possible
No
Type of converter
U converter
Degree of protection (IP)
IP54
Degree of protection (NEMA)
12
Height
630mm
Width
237.7mm
Depth
294mm
Supporting protocol for PROFIsafe
No
Supporting protocol for BACnet
Yes
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
1
Number of interfaces PROFINET
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DG1-34072FN-C54C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output voltage
500V
Power consumption
914W
Mains voltage
380 .. 500V
Mains frequency
50/60 Hz
Relative symmetric net frequency tolerance
10%
Relative symmetric net voltage tolerance
10%
Max. output at linear load at rated output voltage
37kW
Application in industrial area permitted
Number of phases input
3
Number of digital inputs
8
Number of analogue inputs
2
Supporting protocol for ASI
Supporting protocol for KNX
Supporting protocol for CAN
Max. output frequency
400Hz
Max. output at quadratic load at rated output voltage
45kW
Application in domestic- and commercial area permitted
Supporting protocol for PROFINET IO
Number of analogue outputs
2
Supporting protocol for SUCONET
Nominal output current I2N
72A
Supporting protocol for Foundation Fieldbus
Number of digital outputs
1
Supporting protocol for Modbus
Supporting protocol for INTERBUS
Supporting protocol for PROFINET CBA
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for EtherNet/IP
Supporting protocol for TCP/IP
Supporting protocol for LON
With control element
Supporting protocol for SERCOS
Supporting protocol for DeviceNet
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Number of phases output
3
Number of HW-interfaces other
1
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP54
Degree of protection (NEMA)
12
Height
630mm
Width
237.7mm
Depth
294mm
Supporting protocol for PROFIsafe
Supporting protocol for BACnet
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Number of HW-interfaces industrial Ethernet
1
Number of interfaces PROFINET
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
From same serie
Related products