Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output voltage
500V
Mains voltage
380 - 500V
Number of phases output
3
Mains frequency
50/60 Hz
Relative symmetric net voltage tolerance
10%
Nominal output current I2N
46A
Number of analogue outputs
2
Number of phases input
3
Power consumption
818W
Number of analogue inputs
2
Number of digital outputs
1
Max. output at quadratic load at rated output voltage
30kW
Application in industrial area permitted
Yes
With control element
Yes
Relative symmetric net frequency tolerance
10%
Max. output frequency
400Hz
Supporting protocol for TCP/IP
Yes
Supporting protocol for CAN
Yes
Max. output at linear load at rated output voltage
22kW
Supporting protocol for PROFIBUS
Yes
Supporting protocol for ASI
No
Supporting protocol for INTERBUS
No
Supporting protocol for Modbus
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for LON
No
Supporting protocol for Data-Highway
No
Supporting protocol for KNX
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for Foundation Fieldbus
No
Number of digital inputs
8
Application in domestic- and commercial area permitted
Yes
Supporting protocol for SERCOS
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFINET IO
Yes
Number of HW-interfaces serial TTY
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-485
1
Supporting protocol for PROFIsafe
No
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Supporting protocol for EtherNet/IP
Yes
Number of HW-interfaces RS-232
0
Supporting protocol for other bus systems
Yes
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-422
0
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
Yes
Number of HW-interfaces other
1
With optical interface
No
Integrated breaking resistance
Yes
4-quadrant operation possible
Yes
With PC connection
Yes
Type of converter
U converter
Degree of protection (NEMA)
1
Degree of protection (IP)
IP21
Height
558mm
Width
204.6mm
Depth
265.1mm
Related products
From same serie
DG1-34046FB-C21C

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output voltage
500V
Mains voltage
380 .. 500V
Number of phases output
3
Mains frequency
50/60 Hz
Relative symmetric net voltage tolerance
10%
Nominal output current I2N
46A
Number of analogue outputs
2
Number of phases input
3
Power consumption
818W
Number of analogue inputs
2
Number of digital outputs
1
Max. output at quadratic load at rated output voltage
30kW
Application in industrial area permitted
With control element
Relative symmetric net frequency tolerance
10%
Max. output frequency
400Hz
Supporting protocol for TCP/IP
Supporting protocol for CAN
Max. output at linear load at rated output voltage
22kW
Supporting protocol for PROFIBUS
Supporting protocol for ASI
Supporting protocol for INTERBUS
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for Data-Highway
Supporting protocol for KNX
Supporting protocol for PROFINET CBA
Supporting protocol for Foundation Fieldbus
Number of digital inputs
8
Application in domestic- and commercial area permitted
Supporting protocol for SERCOS
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for SUCONET
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFINET IO
Number of HW-interfaces serial TTY
0
Number of interfaces PROFINET
0
Number of HW-interfaces RS-485
1
Supporting protocol for PROFIsafe
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Supporting protocol for EtherNet/IP
Number of HW-interfaces RS-232
0
Supporting protocol for other bus systems
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces RS-422
0
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Number of HW-interfaces other
1
With optical interface
Integrated breaking resistance
4-quadrant operation possible
With PC connection
Type of converter
U converter
Degree of protection (NEMA)
1
Degree of protection (IP)
IP21
Height
558mm
Width
204.6mm
Depth
265.1mm
From same serie
Related products