Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 - 500V
Number of phases output
3
Mains frequency
50/60 Hz
Max. output frequency
400Hz
Relative symmetric net frequency tolerance
10%
Number of phases input
3
Number of analogue inputs
2
Relative symmetric net voltage tolerance
10%
Max. output voltage
500V
Number of digital outputs
1
Application in industrial area permitted
Yes
Power consumption
575W
Number of analogue outputs
2
Supporting protocol for TCP/IP
Yes
Application in domestic- and commercial area permitted
Yes
Nominal output current I2N
38A
With control element
Yes
Max. output at quadratic load at rated output voltage
22kW
Number of digital inputs
8
Max. output at linear load at rated output voltage
18.5kW
Supporting protocol for KNX
No
Supporting protocol for SUCONET
No
Supporting protocol for CAN
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for PROFIsafe
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for ASI
No
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
Yes
Number of HW-interfaces other
1
Supporting protocol for LON
No
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
Yes
4-quadrant operation possible
Yes
Type of converter
U converter
Degree of protection (IP)
IP54
Degree of protection (NEMA)
12
Height
558mm
Width
204.6mm
Depth
265.1mm
Supporting protocol for other bus systems
Yes
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for BACnet
Yes
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DG1-34038FB-C54C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 .. 500V
Number of phases output
3
Mains frequency
50/60 Hz
Max. output frequency
400Hz
Relative symmetric net frequency tolerance
10%
Number of phases input
3
Number of analogue inputs
2
Relative symmetric net voltage tolerance
10%
Max. output voltage
500V
Number of digital outputs
1
Application in industrial area permitted
Power consumption
575W
Number of analogue outputs
2
Supporting protocol for TCP/IP
Application in domestic- and commercial area permitted
Nominal output current I2N
38A
With control element
Max. output at quadratic load at rated output voltage
22kW
Number of digital inputs
8
Max. output at linear load at rated output voltage
18.5kW
Supporting protocol for KNX
Supporting protocol for SUCONET
Supporting protocol for CAN
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet
Supporting protocol for PROFIBUS
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for INTERBUS
Supporting protocol for PROFIsafe
Supporting protocol for EtherNet/IP
Supporting protocol for INTERBUS-Safety
Supporting protocol for ASI
Supporting protocol for SERCOS
Supporting protocol for DeviceNet Safety
Supporting protocol for SafetyBUS p
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Number of HW-interfaces other
1
Supporting protocol for LON
With optical interface
With PC connection
Integrated breaking resistance
4-quadrant operation possible
Type of converter
U converter
Degree of protection (IP)
IP54
Degree of protection (NEMA)
12
Height
558mm
Width
204.6mm
Depth
265.1mm
Supporting protocol for other bus systems
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for BACnet
Number of HW-interfaces RS-422
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces parallel
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces USB
0
Number of HW-interfaces serial TTY
0
From same serie
Related products
We use cookies to enhance your experience.