Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 - 500V
Nominal output current I2N
16A
Mains frequency
50/60 Hz
Max. output at quadratic load at rated output voltage
11kW
Max. output frequency
400Hz
Max. output at linear load at rated output voltage
7.5kW
With control element
Yes
Max. output voltage
500V
Power consumption
293W
Number of analogue outputs
2
Number of phases output
3
Number of digital outputs
1
Number of digital inputs
8
Number of analogue inputs
2
Relative symmetric net frequency tolerance
10%
Supporting protocol for Modbus
Yes
Relative symmetric net voltage tolerance
10%
Supporting protocol for SUCONET
No
Application in industrial area permitted
Yes
Supporting protocol for TCP/IP
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for LON
No
Supporting protocol for INTERBUS
No
Application in domestic- and commercial area permitted
Yes
Supporting protocol for ASI
No
Number of phases input
3
Supporting protocol for Data-Highway
No
Supporting protocol for CAN
Yes
Supporting protocol for PROFINET IO
Yes
Supporting protocol for PROFIBUS
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for KNX
No
Supporting protocol for EtherNet/IP
Yes
With optical interface
No
With PC connection
Yes
Integrated breaking resistance
Yes
Number of HW-interfaces other
1
4-quadrant operation possible
Yes
Degree of protection (IP)
IP21
Type of converter
U converter
Degree of protection (NEMA)
1
Height
419mm
Width
167.8mm
Depth
244.7mm
Number of HW-interfaces RS-232
0
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for PROFIsafe
No
Supporting protocol for BACnet
Yes
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Supporting protocol for other bus systems
Yes
Number of HW-interfaces parallel
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DG1-34016FB-C21C

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
380 .. 500V
Nominal output current I2N
16A
Mains frequency
50/60 Hz
Max. output at quadratic load at rated output voltage
11kW
Max. output frequency
400Hz
Max. output at linear load at rated output voltage
7.5kW
With control element
Max. output voltage
500V
Power consumption
293W
Number of analogue outputs
2
Number of phases output
3
Number of digital outputs
1
Number of digital inputs
8
Number of analogue inputs
2
Relative symmetric net frequency tolerance
10%
Supporting protocol for Modbus
Relative symmetric net voltage tolerance
10%
Supporting protocol for SUCONET
Application in industrial area permitted
Supporting protocol for TCP/IP
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for INTERBUS
Application in domestic- and commercial area permitted
Supporting protocol for ASI
Number of phases input
3
Supporting protocol for Data-Highway
Supporting protocol for CAN
Supporting protocol for PROFINET IO
Supporting protocol for PROFIBUS
Supporting protocol for Foundation Fieldbus
Supporting protocol for SERCOS
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for KNX
Supporting protocol for EtherNet/IP
With optical interface
With PC connection
Integrated breaking resistance
Number of HW-interfaces other
1
4-quadrant operation possible
Degree of protection (IP)
IP21
Type of converter
U converter
Degree of protection (NEMA)
1
Height
419mm
Width
167.8mm
Depth
244.7mm
Number of HW-interfaces RS-232
0
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Number of HW-interfaces RS-485
1
Number of HW-interfaces industrial Ethernet
1
Supporting protocol for PROFIsafe
Supporting protocol for BACnet
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces USB
0
Number of interfaces PROFINET
0
Supporting protocol for other bus systems
Number of HW-interfaces parallel
0
From same serie
Related products