Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
208 - 240V
Mains frequency
50/60 Hz
Number of phases input
3
Max. output frequency
400Hz
Power consumption
89W
Relative symmetric net voltage tolerance
10%
Number of analogue outputs
2
Relative symmetric net frequency tolerance
10%
Application in industrial area permitted
Yes
Nominal output current I2N
6.6A
Number of phases output
3
Supporting protocol for TCP/IP
Yes
Supporting protocol for INTERBUS
No
Supporting protocol for SUCONET
No
Max. output at linear load at rated output voltage
1.1kW
Number of digital inputs
8
Supporting protocol for Data-Highway
No
Max. output at quadratic load at rated output voltage
1.5kW
Supporting protocol for KNX
No
Supporting protocol for ASI
No
Max. output voltage
240V
Supporting protocol for Modbus
Yes
Supporting protocol for DeviceNet
Yes
Number of analogue inputs
2
With control element
Yes
Supporting protocol for CAN
Yes
Supporting protocol for PROFIBUS
Yes
Number of digital outputs
1
Application in domestic- and commercial area permitted
Yes
Number of HW-interfaces other
1
With optical interface
No
Integrated breaking resistance
Yes
With PC connection
Yes
Type of converter
U converter
Degree of protection (NEMA)
12
Degree of protection (IP)
IP54
4-quadrant operation possible
Yes
Height
327mm
Depth
200.9mm
Width
153mm
Supporting protocol for PROFINET IO
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
Yes
Supporting protocol for other bus systems
Yes
Supporting protocol for LON
No
Number of HW-interfaces industrial Ethernet
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Supporting protocol for DeviceNet Safety
No
Number of HW-interfaces RS-422
0
Supporting protocol for PROFIsafe
No
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DG1-326D6FB-C54C

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Mains voltage
208 .. 240V
Mains frequency
50/60 Hz
Number of phases input
3
Max. output frequency
400Hz
Power consumption
89W
Relative symmetric net voltage tolerance
10%
Number of analogue outputs
2
Relative symmetric net frequency tolerance
10%
Application in industrial area permitted
Nominal output current I2N
6.6A
Number of phases output
3
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS
Supporting protocol for SUCONET
Max. output at linear load at rated output voltage
1.1kW
Number of digital inputs
8
Supporting protocol for Data-Highway
Max. output at quadratic load at rated output voltage
1.5kW
Supporting protocol for KNX
Supporting protocol for ASI
Max. output voltage
240V
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Number of analogue inputs
2
With control element
Supporting protocol for CAN
Supporting protocol for PROFIBUS
Number of digital outputs
1
Application in domestic- and commercial area permitted
Number of HW-interfaces other
1
With optical interface
Integrated breaking resistance
With PC connection
Type of converter
U converter
Degree of protection (NEMA)
12
Degree of protection (IP)
IP54
4-quadrant operation possible
Height
327mm
Depth
200.9mm
Width
153mm
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Supporting protocol for other bus systems
Supporting protocol for LON
Number of HW-interfaces industrial Ethernet
1
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-485
1
Supporting protocol for DeviceNet Safety
Number of HW-interfaces RS-422
0
Supporting protocol for PROFIsafe
Number of HW-interfaces serial TTY
0
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
From same serie