Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP21
Height
486mm
Depth
371mm
Width
1035mm
Degree of protection (NEMA)
1
Supporting protocol for SERCOS
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for LON
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for PROFINET CBA
No
Supporting protocol for Modbus
Yes
Supporting protocol for PROFINET IO
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIBUS
Yes
Supporting protocol for CAN
Yes
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Supporting protocol for other bus systems
Yes
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces other
1
Supporting protocol for KNX
No
Supporting protocol for TCP/IP
Yes
Supporting protocol for ASI
No
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Number of analogue inputs
2
With optical interface
No
Number of digital inputs
8
With PC connection
Yes
Nominal output current I2N
312A
4-quadrant operation possible
Yes
Integrated breaking resistance
Yes
Application in domestic- and commercial area permitted
Yes
Max. output frequency
400Hz
Max. output voltage
240V
Max. output at linear load at rated output voltage
75kW
Mains voltage
177 - 264V
Application in industrial area permitted
Yes
Type of converter
U converter
Max. output at quadratic load at rated output voltage
90kW
Number of phases output
3
Number of phases input
3
Relative symmetric net voltage tolerance
10%
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Supporting protocol for BACnet
Yes
With control element
Yes
Number of analogue outputs
2
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DG1-32248FB-C21C
Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Degree of protection (IP)
IP21
Height
486mm
Depth
371mm
Width
1035mm
Degree of protection (NEMA)
1
Supporting protocol for SERCOS
Supporting protocol for INTERBUS-Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for Foundation Fieldbus
Supporting protocol for LON
Supporting protocol for DeviceNet Safety
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for Modbus
Supporting protocol for PROFINET IO
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for other bus systems
Number of HW-interfaces RS-422
0
Number of HW-interfaces parallel
0
Number of HW-interfaces USB
0
Number of HW-interfaces RS-485
1
Number of interfaces PROFINET
0
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces other
1
Supporting protocol for KNX
Supporting protocol for TCP/IP
Supporting protocol for ASI
Number of HW-interfaces RS-232
0
Number of HW-interfaces serial TTY
0
Number of digital outputs
1
Number of analogue inputs
2
With optical interface
Number of digital inputs
8
With PC connection
Nominal output current I2N
312A
4-quadrant operation possible
Integrated breaking resistance
Application in domestic- and commercial area permitted
Max. output frequency
400Hz
Max. output voltage
240V
Max. output at linear load at rated output voltage
75kW
Mains voltage
177 .. 264V
Application in industrial area permitted
Type of converter
U converter
Max. output at quadratic load at rated output voltage
90kW
Number of phases output
3
Number of phases input
3
Relative symmetric net voltage tolerance
10%
Relative symmetric net frequency tolerance
10%
Mains frequency
50/60 Hz
Supporting protocol for BACnet
With control element
Number of analogue outputs
2
From same serie