Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output voltage
240V
Number of phases input
3
Mains frequency
50/60 Hz
Max. output at linear load at rated output voltage
30kW
Relative symmetric net frequency tolerance
10%
Max. output at quadratic load at rated output voltage
37kW
Mains voltage
208 - 240V
Number of phases output
3
Supporting protocol for PROFIBUS
Yes
Nominal output current I2N
114A
Max. output frequency
400Hz
Application in domestic- and commercial area permitted
Yes
Relative symmetric net voltage tolerance
10%
Supporting protocol for ASI
No
Supporting protocol for CAN
Yes
Supporting protocol for Foundation Fieldbus
No
Number of HW-interfaces serial TTY
0
Number of interfaces PROFINET
0
Application in industrial area permitted
Yes
Power consumption
1077W
Number of HW-interfaces parallel
0
Supporting protocol for Modbus
Yes
Number of HW-interfaces RS-422
0
Supporting protocol for SafetyBUS p
No
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for Data-Highway
No
Number of digital inputs
8
Number of analogue inputs
2
Supporting protocol for LON
No
Supporting protocol for PROFINET IO
Yes
Supporting protocol for other bus systems
Yes
Supporting protocol for KNX
No
Supporting protocol for BACnet
Yes
Supporting protocol for DeviceNet
Yes
Supporting protocol for SUCONET
No
Number of HW-interfaces RS-232
0
Number of analogue outputs
2
Number of HW-interfaces RS-485
1
Supporting protocol for PROFIsafe
No
Supporting protocol for INTERBUS
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for AS-Interface Safety at Work
No
Number of HW-interfaces USB
0
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for TCP/IP
Yes
Supporting protocol for INTERBUS-Safety
No
Number of digital outputs
1
With control element
Yes
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces other
1
With optical interface
No
With PC connection
Yes
4-quadrant operation possible
Yes
Integrated breaking resistance
Yes
Degree of protection (IP)
IP54
Type of converter
U converter
Degree of protection (NEMA)
12
Height
888.5mm
Width
288mm
Depth
340.7mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DG1-32114FB-C54C

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output voltage
240V
Number of phases input
3
Mains frequency
50/60 Hz
Max. output at linear load at rated output voltage
30kW
Relative symmetric net frequency tolerance
10%
Max. output at quadratic load at rated output voltage
37kW
Mains voltage
208 .. 240V
Number of phases output
3
Supporting protocol for PROFIBUS
Nominal output current I2N
114A
Max. output frequency
400Hz
Application in domestic- and commercial area permitted
Relative symmetric net voltage tolerance
10%
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for Foundation Fieldbus
Number of HW-interfaces serial TTY
0
Number of interfaces PROFINET
0
Application in industrial area permitted
Power consumption
1077W
Number of HW-interfaces parallel
0
Supporting protocol for Modbus
Number of HW-interfaces RS-422
0
Supporting protocol for SafetyBUS p
Supporting protocol for SERCOS
Supporting protocol for DeviceNet Safety
Supporting protocol for Data-Highway
Number of digital inputs
8
Number of analogue inputs
2
Supporting protocol for LON
Supporting protocol for PROFINET IO
Supporting protocol for other bus systems
Supporting protocol for KNX
Supporting protocol for BACnet
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Number of HW-interfaces RS-232
0
Number of analogue outputs
2
Number of HW-interfaces RS-485
1
Supporting protocol for PROFIsafe
Supporting protocol for INTERBUS
Supporting protocol for PROFINET CBA
Supporting protocol for AS-Interface Safety at Work
Number of HW-interfaces USB
0
Supporting protocol for EtherNet/IP
Supporting protocol for TCP/IP
Supporting protocol for INTERBUS-Safety
Number of digital outputs
1
With control element
Number of HW-interfaces industrial Ethernet
1
Number of HW-interfaces other
1
With optical interface
With PC connection
4-quadrant operation possible
Integrated breaking resistance
Degree of protection (IP)
IP54
Type of converter
U converter
Degree of protection (NEMA)
12
Height
888.5mm
Width
288mm
Depth
340.7mm
From same serie
Related products
We use cookies to enhance your experience.