Technical specifications
Max. output at quadratic load at rated output voltage
7.5kW
Max. output voltage
500V
Nominal output current I2N
18A
Power consumption
304W
Max. output at linear load at rated output voltage
7.5kW
Relative symmetric net voltage tolerance
10%
Number of digital outputs
1
Mains voltage
380 - 480V
Number of analogue outputs
1
With control element
Yes
Number of phases output
3
Number of analogue inputs
2
Supporting protocol for TCP/IP
No
Max. output frequency
500Hz
Supporting protocol for PROFIBUS
No
Number of digital inputs
4
Mains frequency
50/60 Hz
Application in industrial area permitted
Yes
Number of phases input
3
Supporting protocol for Data-Highway
No
Supporting protocol for INTERBUS
No
Supporting protocol for CAN
Yes
Supporting protocol for KNX
No
Supporting protocol for PROFINET IO
No
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for ASI
No
Supporting protocol for PROFINET CBA
No
Relative symmetric net frequency tolerance
10%
Supporting protocol for Modbus
Yes
Supporting protocol for SUCONET
No
Application in domestic- and commercial area permitted
Yes
Number of HW-interfaces other
0
With optical interface
No
With PC connection
Yes
4-quadrant operation possible
Yes
Type of converter
U converter
Integrated breaking resistance
Yes
Degree of protection (IP)
IP66
Degree of protection (NEMA)
4X
Height
310mm
Width
210.5mm
Depth
238mm
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
Yes
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for BACnet
No
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for other bus systems
Yes
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
DC1-34018FB-A66OE1

Details
- Low-voltage industrial components
- Frequency converter =< 1 kV
- 1 KOM
- EATON
Technical specifications
Max. output at quadratic load at rated output voltage
7.5kW
Max. output voltage
500V
Nominal output current I2N
18A
Power consumption
304W
Max. output at linear load at rated output voltage
7.5kW
Relative symmetric net voltage tolerance
10%
Number of digital outputs
1
Mains voltage
380 .. 480V
Number of analogue outputs
1
With control element
Number of phases output
3
Number of analogue inputs
2
Supporting protocol for TCP/IP
Max. output frequency
500Hz
Supporting protocol for PROFIBUS
Number of digital inputs
4
Mains frequency
50/60 Hz
Application in industrial area permitted
Number of phases input
3
Supporting protocol for Data-Highway
Supporting protocol for INTERBUS
Supporting protocol for CAN
Supporting protocol for KNX
Supporting protocol for PROFINET IO
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for ASI
Supporting protocol for PROFINET CBA
Relative symmetric net frequency tolerance
10%
Supporting protocol for Modbus
Supporting protocol for SUCONET
Application in domestic- and commercial area permitted
Number of HW-interfaces other
0
With optical interface
With PC connection
4-quadrant operation possible
Type of converter
U converter
Integrated breaking resistance
Degree of protection (IP)
IP66
Degree of protection (NEMA)
4X
Height
310mm
Width
210.5mm
Depth
238mm
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for BACnet
Number of HW-interfaces industrial Ethernet
0
Supporting protocol for other bus systems
Number of interfaces PROFINET
0
Number of HW-interfaces RS-232
0
Number of HW-interfaces RS-422
0
Number of HW-interfaces serial TTY
0
Number of HW-interfaces RS-485
1
Number of HW-interfaces USB
0
Number of HW-interfaces parallel
0