Aleta.hr
Main Product Image

DC1-322D3FN-A6SOE1

Code: 1871765

ManufacturerRAZNO
Catalog number199412
Type
EAN code4015081978014

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Mains frequency

50/60 Hz

Mains voltage

200 - 240V

Number of phases output

3

Max. output at quadratic load at rated output voltage

11kW

Max. output voltage

250V

Max. output frequency

500Hz

Relative symmetric net frequency tolerance

10%

Nominal output current I2N

2.3A

Number of digital inputs

4

Number of phases input

3

Max. output at linear load at rated output voltage

11kW

Power consumption

14.8W

Application in industrial area permitted

Yes

With control element

Yes

Supporting protocol for CAN

Yes

Supporting protocol for PROFIBUS

No

Supporting protocol for INTERBUS

No

Application in domestic- and commercial area permitted

Yes

Supporting protocol for Data-Highway

No

Supporting protocol for DeviceNet

No

Number of digital outputs

1

Supporting protocol for Modbus

Yes

Relative symmetric net voltage tolerance

10%

Supporting protocol for TCP/IP

No

Number of analogue inputs

2

Supporting protocol for KNX

No

Supporting protocol for ASI

No

Number of analogue outputs

1

Number of HW-interfaces other

0

With optical interface

No

With PC connection

Yes

Integrated breaking resistance

No

4-quadrant operation possible

No

Type of converter

U converter

Degree of protection (IP)

IP66

Degree of protection (NEMA)

4X

Height

232mm

Width

161mm

Depth

162mm

Supporting protocol for LON

No

Supporting protocol for PROFINET IO

No

Supporting protocol for SUCONET

No

Supporting protocol for SERCOS

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for EtherNet/IP

Yes

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for BACnet

No

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Supporting protocol for other bus systems

Yes

Number of interfaces PROFINET

0

Number of HW-interfaces RS-232

0


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


Related products


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

DC1-322D3FN-A6SOE1

Main Product Image

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • EATON

Technical specifications

Mains frequency

50/60 Hz

Mains voltage

200 .. 240V

Number of phases output

3

Max. output at quadratic load at rated output voltage

11kW

Max. output voltage

250V

Max. output frequency

500Hz

Relative symmetric net frequency tolerance

10%

Nominal output current I2N

2.3A

Number of digital inputs

4

Number of phases input

3

Max. output at linear load at rated output voltage

11kW

Power consumption

14.8W

Application in industrial area permitted

With control element

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for INTERBUS

Application in domestic- and commercial area permitted

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Number of digital outputs

1

Supporting protocol for Modbus

Relative symmetric net voltage tolerance

10%

Supporting protocol for TCP/IP

Number of analogue inputs

2

Supporting protocol for KNX

Supporting protocol for ASI

Number of analogue outputs

1

Number of HW-interfaces other

0

With optical interface

With PC connection

Integrated breaking resistance

4-quadrant operation possible

Type of converter

U converter

Degree of protection (IP)

IP66

Degree of protection (NEMA)

4X

Height

232mm

Width

161mm

Depth

162mm

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for INTERBUS-Safety

Supporting protocol for DeviceNet Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for PROFINET CBA

Supporting protocol for BACnet

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces USB

0

Number of HW-interfaces RS-485

1

Number of HW-interfaces serial TTY

0

Number of HW-interfaces RS-422

0

Number of HW-interfaces parallel

0

Supporting protocol for other bus systems

Number of interfaces PROFINET

0

Number of HW-interfaces RS-232

0

From same serie

Related products

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.